— 38 —
on typical group usage, program appropriate
Threshold (%):
,
Time
On (Sec):
and
Time Off (Sec):
settings.
SCA Loss
Stations running an SCA subcarrier first need to set up the
proper measurement parameters on the
Tuner
menu (Page 19).
Only then should this alarm be used. Current
SCA Injection (%):
is shown so that threshold and timing sliders may be set
appropriately. Note that this alarm signals loss of the
subcarrier only, not loss of SCA audio.
Alarm Logging
In addition to local dis-
plays/tallies and SMS
or email alerts for sig-
nal and programming
faults, all alarms are
logged and stored. You
can click
View Alarm
Log
at the bottom of
the page for a display
of all alarms in order
of time and date.
The log holds data on
the type of
Alarm
, which
monitored
Station
it
pertains to (important
when the StationRota-
tion feature is active),
the
Time
and
Date
re-
ceived plus the alarm
Duration
.
You may
View Alarm Log
on your screen and even filter the re-
sults by overtyping
Filter alarms…
with a search term from an
appropriate column.
You may also download the Alarm Logs for
Daily
,
Weekly
,
Monthly
or
Complete
(all alarms) time periods. The number of alarms re-
ceived for these time periods is shown on the right above the
listing. Downloads are saved to your computer as small .csv
text files.
The Alarm Log will continue to accumulate entries indefinitely.
Clear it completely at any time by clicking the
Clear Alarm Logs
bar. This will delete all entries. You’ll be asked to confirm this
action, at which point you might decide first to download the
Complete
log of all alarms to be on the safe side.