Figure 5-71
Figure 5-72
Please refer to the following sheet for detailed information.
Parameter Function
Event
Type
The abnormal events include: No disk, disk error, disk no space, net
disconnection, IP conflict and MAC conflict.
User can set one or more items here.
Less than: User can set the minimum percentage value here (For disk
not space only). The device can alarm when capacity is not sufficient.
User need to draw a circle to enable this function.
Enable
Check the box here to enable selected function.
Alarm Out
Please select corresponding alarm output channel when an alarm
occurs. User need to check the box to enable this function.
Latch
The alarm output can delay for the specified time after an alarm stops.
The value ranges from 1s to 300s.
Show
message
System can pop up a message to alarm user in the local host screen if
user enabled this function.
Alarm
upload
System can upload the alarm signal to the centre (Including alarm
centre.
Send
Email
If user enabled this function, System can send out an email to alert user
when an alarm occurs.
Summary of Contents for DNA3300 Series
Page 29: ...3 5 2 DNA3700 Series Please refer to Figure 3 2 for connection sample Figure 3 2...
Page 88: ...Figure 4 81 Figure 4 82...
Page 89: ...Figure 4 83 Figure 4 84...
Page 95: ...Figure 4 89 Figure 4 90...
Page 96: ...Figure 4 91 Figure 4 92...
Page 97: ...Figure 4 93 Figure 4 94...
Page 99: ...Figure 4 96 Figure 4 97...
Page 102: ...Figure 4 99 Figure 4 100...
Page 137: ...Figure 4 143 Figure 4 144...
Page 178: ...Figure 5 53 Figure 5 54...
Page 179: ...Figure 5 55 Figure 5 56 Figure 5 57...
Page 183: ...Figure 5 61 Figure 5 62...