Chapter 2 OPERATION
1. BASIC FUNCTION EXPLANATION
After connect all wirings as the instruction and turn on the power, the dome camera will display
it’s configure information. And after configuration is done, the menu will show configure OK
information. If the user sets the POWER UP DONE, the dome will execute this movement and
the tips information disappear; if the user does not set the POWER UP DONE, the tips
information will be kept until the dome camera receive the control command, then the tips
information will disappear and show the system communication control is normal.
Power up display:
When configuring:
Configure OK:
NOTE:
1. VERSION 1.10 is the software version number of the dome camera, and it will change
as the product’s upgrade.
2. PROTOCOL P is control agreement, can support P, D protocol, and it will change as
the dial switch chooses different protocol.
3. ADDRESS 1 is control address, can support 256 addresses, and it will change as the
dial switch chooses different protocol.
4. COMM 4800.N.8.1 is communication information, 4800 is communication baud rate,