8. Operation. 

 

Before the pump is started for operation, the rotation direction must be checked. At start the 

motors starting torque will cause the pump to jerk, and therefore has the pump to be mounted firm 

to the base.  

Before start, the pump must be fully assembled and ready for operation. 

At wrong start rotation, two phases must be switched. See the connection diagram. 

                Wrong rotation or cavitation in the pump can make loud noise.             

                 

 NOTE.

  

If danger of freezing exists, isolate the pump by closing the valve in the pump suction line and 

discharge 

and 

drain the pump completely. 

 

 

9. Service & maintenance. 

 

Before any inspection, service or repair of the pump, it has to be physically disconnected from 

the power supply. Remove connectors or dismount the wires from the electric board. An 

emergency stop can be released

 

accidental or be defective and start the pump by mistake. 

 

All pumps require regular service and preventive maintenance to operate economically and reliably. 

The pump should be checked every 6 months and during possible extreme operating conditions more often.  

For complete overhaul of the pump contact an authorized pumps workshop or your local DanPumps dealer. 

Clean the pump carefully before dismantling it. Follow local and national safety instructions. 

Bearings in our DanPumps are lubricated for lift, and don´t need re-lubrication. 

 

Typical duty hours for motor with lifetime lubricated bearings. 

 

Frame size                 Poles                 Typical lifetime 

56 - 160                      2 - 8                        40,000h 

180                             2 - 4                        35,000h 

200                             2 - 4                        27,000h 

225                             2 - 4                        23,000h 

180 - 225                    4 - 8                        40,000h 

 

 

If the mechanical seal need visually inspection or have to be replaced, then never use hydrocarbon liquids 

(oil or solvent) to clean mechanical seal parts. Use of oil or solvent will deteriorate material used on the seal. 

Use mild soap solution to clean seal parts. Use only your finger to remove dirt. Rinse with clean water and 

dry with mild air stream. Use care not to damage or scratch the delicate surfaces.   

 

Check O-rings for cracks or tears. 

   

Note for the electrical motor: Make sure the fan cover is clean which enable the fan wing to cool the motor.  

 

 

 

 

Pumps manufactured with plug-in shaft, has a gap of 4 

mm. between the back plate and adapter neck.   

Please see picture. 

 

 

 

 

Summary of Contents for S-IP

Page 1: ...In Line Pumps models S IP S MP End of life pump has to be recycled in accordance with local regulations Version 1 0 2017 ...

Page 2: ...ter saltwater and water with small contaminants Impeller is a closed model S IP and S MP pumps are as standard assembled with Svend Hoyer electro motor Option S IP and S MP pumps can be ordered with other motor brands like ABB or BEVI Option Frequency Converter Drive direct mounted on the motor Option ATEX motor A22 II 3D Ex tc IIIB T120 ExnA II 3G Ex nA IIC T3 Option Forced Fan Cooling Option Bea...

Page 3: ...EN1092 1 Pump is based on design according ISO 2858 Pump Standard surface treatment Blue RAL 5010 C5M Only if it is built in into the motor Motor protection Degree of protection is standard IP55 and insulation class is F Tested to standard IEC 60034 2 1 The IE2 class motor has standard tropical windings The IE3 class motor has tropical windings as an option Pump material Pump materiale as standard...

Page 4: ...Pump dimensions ...

Page 5: ... piping into place by tightening the flange bolts Pipes should be supported near the pump Never run the pump with suction side and discharge side blocked simultaneously Only shunt the pump on the discharge side Cavitation in the pump volute may occur if the pump s suction becomes obstructed Cavitation can cause damage to the internal elements of the pump especially on the impeller Always provide t...

Page 6: ...ched off and cannot be switched on again accidental This also applies to the auxiliary power circuits e g anti condense heaters Check that supply voltage and frequency are the same as rated data Motors can be used with a supply deviation of 5 voltage and 2 frequency according to IEC60034 1 Connection diagrams for main supply and accessory as PTC or heater are located inside the terminal box Connec...

Page 7: ...6 months and during possible extreme operating conditions more often For complete overhaul of the pump contact an authorized pumps workshop or your local DanPumps dealer Clean the pump carefully before dismantling it Follow local and national safety instructions Bearings in our DanPumps are lubricated for lift and don t need re lubrication Typical duty hours for motor with lifetime lubricated bear...

Page 8: ...correct for the pump Water level in the well is too low open tank Impeller is partially clogged Pump vibrates Wear ring is worn Air inside pump house or periodically sucked into the pump The impeller is clogged Excessively high suction lift Seal not correct for the medie Pump has been running dry Pump is not running the right way The pump back pressure is too low The pump is missing 1 phase in the...

Page 9: ...tions which give the pump a unique composition In order to find the correct spare parts for the pump then always inform about the pump serial number You will find the serial number on the DanPumps wet end label See page 2 Model pump with plug in shaft Model Pump with claw clutch 2L ...

Page 10: ......

Page 11: ......

Page 12: ...12 CE Declaration ...

Page 13: ...Nordager 25 DK 6000 Kolding Denmark Tel 45 86 571 344 www sonflow dk ...

Reviews: