1. Manual content.

 

 

 

1.  Pump labels. 

2.  Applications. 

3.  Technical specification. 

4.  Handling. 

5.  Pump installation. 

6.  Electrical installation. 

7.  Operation. 

8.  Service & maintenance. 

9.  CE Declaration.  

10. Trouble shooting. 

11. Spare parts. 

 

 

 2. Pump labels. 

 

       

     

 

  

 

                      

Danpumps wet-end label.

 

 

                  Motor label example. 

 

 

 

 

 

Technical information is subject to change without notice. 

 

 

3. 

Applications

 

This installation and service manual are valid to pump type S-IP and S-MP series.  

S-IP and S-MP pumps are single stage, and non-self-priming pumps. 

The pumps are constructed as in-line model, and driven with a standard norm electro motor.  

The pumps are designed for clean water, saltwater and water with small contaminants.  

Impeller is a closed model. 

S-IP and S-MP pumps are as standard assembled with Svend-Hoyer electro motor.  

  Option: S-IP and S-MP pumps can be ordered with other motor brands like ABB or BEVI.  

  Option: Frequency Converter Drive direct mounted on the motor. 

  Option: ATEX motor.  A22 (II 3D Ex tc IIIB T120) & ExnA (II 3G Ex nA IIC T3) 

  Option: Forced Fan Cooling. 

  Option: Bearing temperature sensor. 

  Option: IP56 / IP65. 

  Option: SIC/SIC Mech. Seal. 

  Option: Automatic Aspirator unit. 

 

 

   WARNING.   

 

The pump must never be used in flammable or explosive media. If there are local restrictions concerning fire 

risks, they must be obeyed at all time. 

The pump meet EU’s machine directive, see declaration of conformity in this manual. 

The individual national country and local standards has at all time to be observed. 

   

 

Summary of Contents for S-IP

Page 1: ...In Line Pumps models S IP S MP End of life pump has to be recycled in accordance with local regulations Version 1 0 2017 ...

Page 2: ...ter saltwater and water with small contaminants Impeller is a closed model S IP and S MP pumps are as standard assembled with Svend Hoyer electro motor Option S IP and S MP pumps can be ordered with other motor brands like ABB or BEVI Option Frequency Converter Drive direct mounted on the motor Option ATEX motor A22 II 3D Ex tc IIIB T120 ExnA II 3G Ex nA IIC T3 Option Forced Fan Cooling Option Bea...

Page 3: ...EN1092 1 Pump is based on design according ISO 2858 Pump Standard surface treatment Blue RAL 5010 C5M Only if it is built in into the motor Motor protection Degree of protection is standard IP55 and insulation class is F Tested to standard IEC 60034 2 1 The IE2 class motor has standard tropical windings The IE3 class motor has tropical windings as an option Pump material Pump materiale as standard...

Page 4: ...Pump dimensions ...

Page 5: ... piping into place by tightening the flange bolts Pipes should be supported near the pump Never run the pump with suction side and discharge side blocked simultaneously Only shunt the pump on the discharge side Cavitation in the pump volute may occur if the pump s suction becomes obstructed Cavitation can cause damage to the internal elements of the pump especially on the impeller Always provide t...

Page 6: ...ched off and cannot be switched on again accidental This also applies to the auxiliary power circuits e g anti condense heaters Check that supply voltage and frequency are the same as rated data Motors can be used with a supply deviation of 5 voltage and 2 frequency according to IEC60034 1 Connection diagrams for main supply and accessory as PTC or heater are located inside the terminal box Connec...

Page 7: ...6 months and during possible extreme operating conditions more often For complete overhaul of the pump contact an authorized pumps workshop or your local DanPumps dealer Clean the pump carefully before dismantling it Follow local and national safety instructions Bearings in our DanPumps are lubricated for lift and don t need re lubrication Typical duty hours for motor with lifetime lubricated bear...

Page 8: ...correct for the pump Water level in the well is too low open tank Impeller is partially clogged Pump vibrates Wear ring is worn Air inside pump house or periodically sucked into the pump The impeller is clogged Excessively high suction lift Seal not correct for the medie Pump has been running dry Pump is not running the right way The pump back pressure is too low The pump is missing 1 phase in the...

Page 9: ...tions which give the pump a unique composition In order to find the correct spare parts for the pump then always inform about the pump serial number You will find the serial number on the DanPumps wet end label See page 2 Model pump with plug in shaft Model Pump with claw clutch 2L ...

Page 10: ......

Page 11: ......

Page 12: ...12 CE Declaration ...

Page 13: ...Nordager 25 DK 6000 Kolding Denmark Tel 45 86 571 344 www sonflow dk ...

Reviews: