background image

ZG179    2/13 r

ev C

PRESSURIZED FILTER SYSTEM

   CPF250/PF225 

     05410/84535  

   05415/84525 

   CPF500/PF450 

     05420/84515  

   05425/84505 

   CPF1000/PF900 

     05430/84575 

   05435/84565

   CPF2000/PF1900 

     05440/84555  

   05445/84545

 

PRESSURE FILTER  

   ITEM NO.                    ITEM NO. 

 

       SERIES 

            (No UV Clarifier)      (With UV Clarifier)

Pour afficher les instructions en français s'il vous plaît visitez 

http://www.dannermfg.com/Store/instructions.aspx

Summary of Contents for PONDMASTER HAMPTON CPF250 Series

Page 1: ...50 05420 84515 05425 84505 CPF1000 PF900 05430 84575 05435 84565 CPF2000 PF1900 05440 84555 05445 84545 PRESSURE FILTER ITEM NO ITEM NO SERIES No UV Clarifier With UV Clarifier Pour afficher les instr...

Page 2: ...bacteria on the surface of the media that converts dissolved toxic nitrogenous waste to harmless compounds When the bacteria are given the proper environment they grow in a thin biofilm on the surface...

Page 3: ...AL ACCESSORIES for use with your pressurized filter A B C PRO SKIMMERS B PRO BIOLOGICAL FILTER AND FALLS A PRESSURIZED FILTER CHECK VALVE Provide an enclosure for the water pump and keep debris away f...

Page 4: ...ump you will need the following items to set up the filter Hoses Maximum11 2 Flexible pressure hose recommended Note that a Valved Bypass must be incorporated into any high volume system with pumps ov...

Page 5: ...NIT FROM ITS POWER SOURCE BEFORE INSTALLING OR SERVICING DO NOT REACH REMOVE OR DISASSEMBLE BEFOREYOU DISCONNECT POWER Note that the hose fittings of your pressure filter vary depending on your model...

Page 6: ...Pad fits into the top tray BioMatrix filter ball media is used in the bottom tray or trays depending on your model If your BioMatrix filter ball media is packed in plastic bags empty them evenly into...

Page 7: ...surfaces of cover and filter case clean of any dirt sand or debris before reassembling BLUE LEVER UP Maximum flow MOVE BLUE LEVER DOWN Reduced flow down to no flow Valve closed BLUE LEVER DOWN PIVOT...

Page 8: ...e switch by forcing the micro switch Never look directly at UV bulb the UV rays are harmful to eyes and skin TOP CAP ON OFF UV SWITCH UV INDICATOR LIGHT The UV bulb will need replacing We recommend ch...

Page 9: ...xi mately 1 8 turn until it stops The Quartz Sleeve is now unlocked Quartz Sleeve Removal Bulb Removal 1 Disconnect power remove filter cover and place upside down on a stable surface 3 Invert place B...

Page 10: ...PF1900 A B C D E F G H I J K L M N O P 15430 15440 15451 15456 15470 15471 Picture Reference Only 15427 15428 15415 15425 15420 15420 Picture Reference Only 15480 15481 Picture Reference Only 15475 No...

Page 11: ...ler the manufacturer their representatives or any other parties do not constitute warranties and shall not be relied upon by the user and are not part of this contract Neither the seller nor the manuf...