fused
disconnect
switch
Typical wiring for PV
array-direct system
(no battery)
Example: 36V
For a 24V system, modules are
wired in groups of 2 instead of 3.
For a 48V system, modules are
wired in groups of 4 instead of 3.
Explanation
3 modules in series increases
volts to 36.
2 or more sets in parallel increases
the amps & watts.
A controller (current booster) is NOT
required with SunCentric™ pumps.
Dankoff Solar Products, Inc.
Ground the array framework to
earth for lightning protection.
Do NOT ground the power negative.
pump motor
Photovoltaic (PV) modules (panels)
<––– 3 in series makes 36V –––>
C
entric
un
S
TM
Voltag
ge Table for PV-Direct System
Nominal Volts
1 2
2 4
3 6
"nominal" = the NAME of the voltage standard
Working volts
1 6
3 2
4 8
in full sun with pump running +/– 10%
Open Circuit Volts
2 0
4 0
6 0
with pump disconnected in medium-full sun +/– 10%