background image

drain plug at the bottom of the pump.

Safety in case of leakage: A worn shaft seal will cause water leakage. Install the pump 
so that water leakage will not submerge the pump or cause damage to the surroundings.

Overload Protection

Electrical overload can be caused by large debris or a mechanical fault in your pump or by 
an electrical fault in the motor or in your wiring. If protection is not provided, this can cause 
damage to your motor or other parts of your power system, including fire hazard. A circuit 
breaker or fuse is the electrical “safety valve” that prevents such damage.

WARNING: Failure to install the required fuse or

circuit breaker will void your warranty.

Amp rating of fuse or breaker: Ampere rating = amps at the pump + 15-25%. Refer to 
the performance chart for amps at the pump for your application.

Breakers:  Most AC breakers cannot be used for DC circuits. Square-D

®

 QO or QB-Series 

breakers are an exception. They are UL-listed for low voltage DC systems up to 24V 
nominal. They are commonly available at electric supply stores.

Fuses:  Plastic plug-type automotive fuses are good for 24V nominal, 30 Amp Max. Paper 
cartridge type FRN-R time-delay fuses are available for 30 amp maximum and are rated to 
120VDC. A standard AC single-phase fused disconnect switch can be obtained to hold FRN 
fuses. Do not use the small glass type of fuse. Keep spare fuses nearby. DO NOT substitute 
a larger fuse to solve a problem. Place the fuse or breaker close to the power source, rather 
than at the motor, so that it protects against both wiring and motor faults.

Wire Sizing

Wire of sufficient size should be used to keep voltage drop to less than 3%. Greater voltage 
drop has a disproportionate effect on the performance of the pump, and can result in little or 
no water reaching the outlet. Please consult a wire sizing chart that is appropriate for the 
voltage of your system. Your Dankoff Solar Pump supplier can obtain this chart for you.

Direction of Rotation

The pump must run in direction of the arrow on the pump case (counterclockwise when 
facing the pump intake). The direction of rotation is determined by the polarity of the 
electrical connection to the motor. Check for proper direction of rotation by observing the 
motor shaft when power is first applied. Reversal of the polarity (direction) for a few minutes 
will not cause any damage.

Summary of Contents for SunCentric Series

Page 1: ...array tilts to follow the sun as it travels accross the sky Centrifugal pumps loose capacity quickly as solar intensity and motor speed decrease Therefore it is most economical to use a tracking array...

Page 2: ...motive fuses are good for 24V nominal 30 Amp Max Paper cartridge type FRN R time delay fuses are available for 30 amp maximum and are rated to 120VDC A standard AC single phase fused disconnect switch...

Page 3: ...watts A controller current booster is NOT required with SunCentric pumps Dankoff Solar Products Inc Ground the array framework to earth for lightning protection Do NOT ground the power negative pump...

Page 4: ...foot valve must be used at the water intake to keep the pump primed Foot valves are available from any local pump supplier and from many hardware stores To prevent air from being drawn into suction p...

Page 5: ...p of pump Air will be trapped at top of pump Water leak will damage motor Air will be trapped here NO Air will be trapped here NO INLET PIPE OUTLET PIPE YES NO IF water source is higher than the pump...

Page 6: ...to stop the flow upon filling a tank However if the flow is 100 stopped there is danger that the water in the pump can get very hot from fluid friction and cause damage A float valve installation shou...

Page 7: ...ge of water due to a worn shaft seal Be sure that this rubber slinger rotates with the motor shaft If it is cracked or if it does not turn with the shaft either replace it or glue it to the shaft coup...

Page 8: ...ircuit voltage should be about 20V per 12V increment Array is positioned wrong Partial shade or dirt on the PV array Pump is partly jammed See Pump is jammed below Undersized wire see next line IF sys...

Page 9: ...the pump s suction capacity This is called cavitation Lower the pump closer to the water source if possible Reduce friction in the intake pipe by using larger pipe and or eliminating sharp 90 degree e...

Page 10: ...warranty Product liability except where mandated by law is limited to repair or replacement at the discretion of the manufacturer Manufacturer is not responsible for incidental or consequential damage...

Page 11: ...73 2 61 1 34 0 46 0 18 0 07 2 0 7 6 10 6 3 16 1 64 0 55 0 21 0 08 0 02 2 2 8 3 13 3 3 79 1 96 0 67 0 25 0 09 0 03 2 4 9 1 14 9 4 44 2 31 0 79 0 30 0 11 0 04 2 6 9 9 5 15 2 66 0 90 0 35 0 14 0 05 2 8 1...

Reviews: