GENER
AL INFORMA
TION
PR
ODUC
T INFORMA
TION
SY
STEM DESIGN
INTEGR
ATION INT
O SY
STEM
ORDERING INFORMA
TION
Dimensions
CDS303 Frequency
converter
Drive supply voltage
D
ri
ve
p
ow
er k
W
C
om
pr
es
sor
vo
lt
age
c
o
de
C
om
pr
es
sor
m
o
de
l
IP20
IP55
D
riv
e enc
lo
su
re
Overall drive size
[H x W x L]
mm
(inch)
Overall drive size
[H x W x L] mm
(inch)
incl. decoupling
plate
Clearance
above/
below
mm
(inch)
D
riv
e enc
lo
su
re
Overall drive size
[H x W x L] mm
(inch)
Overall drive
size
[H x W x L]
mm
(inch)
incl.
decoupling
plate
Clearance
above/
below
mm
(inch)
T2: 200-240/3/50-60
11
J VZH052-065 B4
520x230x242
(20.47x9.06x9.53)
595x230x242
(23.43x9.06x9.53)
200
(8)
B2
650x242x260
(25.59x9.53x10.24)
-
200
(8)
T4: 380-480/3/50-60
11*
G
VZH052
B3
399x165x249
(15.71x6.5x9.8)
420x165x249
(16.54x6.5x9.8)
100
(4)
B1
480x242x260
(18.90x9.53x10.24)
-
100
(4)
15
VZH065
B3
399x165x249
(15.71x6.5x9.8)
420x165x249
(16.54x6.5x9.8)
100
(4)
B1
480x242x260
(18.90x9.53x10.24)
-
100
(4)
T6: 525-600/3/50-60
15
H
VZH052
B3
399x165x249
(15.71x6.5x9.8)
420x165x249
(16.54x6.5x9.8)
100
(4)
B1
480x242x260
(18.90x9.53x10.24)
-
100
(4)
22
VZH065
B4
520x230x242
(20.47x9.06x9.53)
595x230x242
(23.43x9.06x9.53)
200
(8)
B2
650x242x260
(25.59x9.53x10.24)
-
200
(8)
L
H
W
Min 100/200
Clearance above for cooling
Min 100/200
Clearance above for cooling
Frequency converter dimensions depend
on supply voltage, IP rating and power. The
table below gives an overview of the overall
dimensions and different drive enclosures (B1 -
B4). Details for each drive enclosure are on the
following pages.
Enclosure
Height
Width
Depth
Mounting hole
Max. Weight
Frame
IP Class
A
A
1)
a
B
b
C
d
e
f
(mm) (inch) (mm) (inch) (mm) (inch) (mm) (inch) (mm) (inch) (mm) (inch) (mm) (inch) (mm) (inch) (mm) (inch) kg
lb
B1
IP55
480 18.9
-
-
454 17.87 242 9.53 210 8.27 260 10.24 19
0.75
9
0.35
9
0.35
23
51
B2
IP55
650 25.59
-
-
624 24.57 242 9.53 210 8.27 260 10.24 19
0.75
9
0.35
9
0.35
27
60
B3
IP20
399 15.71 420 16.54 380 14.96 165
6.5
140 5.51 249 9.80
12
0.47
6.8
0.27
7.9
0.31
12
26
B4
IP20
520 20.47 595 23.43 495 19.49 230 9.06 200 7.87 242 9.53
-
-
8.5
0.33
15
0.59
23
51
A
1)
Including decoupling plate.
The dimensions are only for the physical units, but when installing in an application it is necessary to add space for free air passage both above and below the units.
The amount of space for free air passage is listed in “frequency converter dimensions - Clearance above/below (mm/inch)”.
Variable speed compressor package VZH065 (voltage code G) + CDS303 (T4, 11kW) is qualified, to be used at drive supply voltage 380-440V (3 phase, 50/60Hz).
Any further information please contact local Danfoss engineers.
PR
ODUC
T INFORMA
TION
12
AB237586440343en-000601