Table 66: UAUX shutdown error (0x3299 / 0x155)
Code
PROFINET
®
code
Name
Severity (warning/error/
trip lock)
Description
LCP name
0x3299
0x155
U
AUX
shutdown
error
Error
Error when U
AUX
is in shut-
down phase.
UAUX shtdwn
err
9.3.32 UAUX undervoltage hardware (0x329A / 0x156)
This error is valid for PSM 510, DAM 510, and ACM 510.
Table 67: UAUX undervoltage hardware (0x329A / 0x156)
Code
PROFINET
®
code
Name
Severity (warning/
error/trip lock)
Description
LCP name
0x329A
0x156
U
AUX
undervoltage
hardware
Error
U
AUX
undervoltage detected by
hardware circuit.
AUX undervol
HW
9.3.33 Automated fault reset failure (0x329B / 0x168)
This error is valid for PSM 510, DAM 510, and ACM 510.
Table 68: Automated fault reset failure (0x329B / 0x168)
Code
PROFINET
®
code
Name
Severity (warning/
error/trip lock)
Description
LCP name
0x329B
0x168
Automated fault re-
set failure
Trip lock
Too many auto fault resets have been
executed in the intended time interval.
afr failure
9.3.34 Device overtemperature (0x4210 / 0x157)
This error is valid for PSM 510, DAM 510, and ACM 510.
Table 69: Device overtemperature (0x4210 / 0x157)
Code
PROFINET
®
code
Name
Severity (warn‐
ing/error/trip
lock)
Description
LCP name
0x4210
0x157
Device over-
temperature
Warning, error
Triggered when the maximum temperature of the
main device component is exceeded.
PSM: Thyristor rectifier module.
DAM: Maximum temperature of both high side and
low side IGBTs.
overtemp
device
Diagnostics
Operating Guide | VLT® Multiaxis Servo Drive MSD 510 System
AQ262450196490en-000101 / 175R1170| 179
Danfoss A/S © 2019.10