11.9.
Troubleshooting
The Remote Operator display and status indication LEDs can indicate abnormal operating and
system conditions.
Display
Indication
Problem
Possible Solution
nEt
on
display
A loss of communication
has been detected on the
RS485 link to the network.
The Remote Operator has an RS485 Network Timeout
Protection setting (Parameter 3). This error is reported when
no communication occurs for longer than the timeout setting.
The system will become active as soon as communication is
restored.
To clear
nEt
from the display, press the Data/Prog pushbutton
momentarily or send a Reset command from the network
Master.
SP
flashing
on display
Soft starter is off and being
programmed from the serial
network.
Finish soft starter network programming procedure and exit
Programming Mode.
12.
Appendix B - Specifications
Enclosure
Dimensions ............................................................................... 35 mm (W) x 157 mm (H) x 90 mm (D)
Weight ....................................................................................................................................... 250 g
Protection ..................................................................................................................................... IP20
Mounting
Spring-action plastic mounting clips (x 2)
Connections
Soft starter ............................................................................................................. 6-way pin assembly
Network .......................................................... 5-way male and unpluggable female connector (supplied)
Maximum cable size ................................................................................................................ 2.5 mm
2
Settings
Protocol ............................................................................................................. Modbus RTU, AP ASCII
Address range ........................................................................................................................... 0 to 31
Data rate (bps) ............................................................................................. 4800, 9600, 19200, 38400
Parity .............................................................................................................. None, Odd, Even, 10-bit
Timeout ..................................................................................................... None (off), 10 s, 60 s, 100 s
Certification
C
9
............................................................................................................................. IEC 60947-4-2
CE .............................................................................................................................. IEC 60947-4-2