23-54
Reset
Energy
Log
23-6*
Trending
23-60
Trend
Variable
23-61
Continuous
Bin
Data
23-62
Timed
Bin
Data
23-63
Timed
Period
Start
23-64
Timed
Period
Stop
23-65
Minimum
Bin
Value
23-66
Reset
Continuous
Bin
Data
23-67
Reset
Timed
Bin
Data
23-8*
Payback
Counter
23-80
Power
Reference
Factor
23-81
Energy
Cost
23-82
Investment
23-83
Energy
Savings
23-84
Cost
Savings
24-**
Appl.
Functions
2
24-0*
Fire
Mode
24-00
Fire
Mode
Function
24-01
Fire
Mode
Configuration
24-02
Fire
Mode
Unit
24-03
Fire
Mode
Min
Reference
24-04
Fire
Mode
Max
Reference
24-05
Fire
Mode
Preset
Reference
24-06
Fire
Mode
Reference
Source
24-07
Fire
Mode
Feedback
Source
24-09
Fire
Mode
Alarm
Handling
24-1*
Drive
Bypass
24-10
Drive
Bypass
Function
24-11
Drive
Bypass
Delay
Time
24-9*
Multi-Motor
Funct.
24-90
Missing
Motor
Function
24-91
Missing
Motor
Coefficient
1
24-92
Missing
Motor
Coefficient
2
24-93
Missing
Motor
Coefficient
3
24-94
Missing
Motor
Coefficient
4
24-95
Locked
Rotor
Function
24-96
Locked
Rotor
Coefficient
1
24-97
Locked
Rotor
Coefficient
2
24-98
Locked
Rotor
Coefficient
3
24-99
Locked
Rotor
Coefficient
4
25-**
Cascade
Controller
25-0*
System
Settings
25-00
Cascade
Controller
25-02
Motor
Start
25-04
Pump
Cycling
25-05
Fixed
Lead
Pump
25-06
Number
of
Pumps
25-2*
Bandwidth
Settings
25-20
Staging
Bandwidth
25-21
Override
Bandwidth
25-22
Fixed
Speed
Bandwidth
25-23
SBW
Staging
Delay
25-24
SBW
Destaging
Delay
25-25
OBW
Time
25-26
Destage
At
No-Flow
25-27
Stage
Function
25-28
Stage
Function
Time
25-29
Destage
Function
25-30
Destage
Function
Time
25-4*
Staging
Settings
25-40
Ramp
Down
Delay
25-41
Ramp
Up
Delay
25-42
Staging
Threshold
25-43
Destaging
Threshold
25-44
Staging
Speed
[RPM]
25-45
Staging
Speed
[Hz]
25-46
Destaging
Speed
[RPM]
25-47
Destaging
Speed
[Hz]
25-5*
Alternation
Settings
25-50
Lead
Pump
Alternation
25-51
Alternation
Event
25-52
Alternation
Time
Interval
25-53
Alternation
Timer
Value
25-54
Alternation
Predefined
Time
25-55
Alternate
if
Load
<
50%
25-56
Staging
Mode
at
Alternation
25-58
Run
Next
Pump
Delay
25-59
Run
on
Mains
Delay
25-8*
Status
25-80
Cascade
Status
25-81
Pump
Status
25-82
Lead
Pump
25-83
Relay
Status
25-84
Pump
ON
Time
25-85
Relay
ON
Time
25-86
Reset
Relay
Counters
25-9*
Service
25-90
Pump
Interlock
25-91
Manual
Alternation
26-**
Analog
I/O
Option
26-0*
Analog
I/O
Mode
26-00
Terminal
X42/1
Mode
26-01
Terminal
X42/3
Mode
26-02
Terminal
X42/5
Mode
26-1*
Analog
Input
X42/1
26-10
Terminal
X42/1
Low
Voltage
26-11
Terminal
X42/1
High
Voltage
26-14
Term.
X42/1
Low
Ref./Feedb.
Value
26-15
Term.
X42/1
High
Ref./Feedb.
Value
26-16
Term.
X42/1
Filter
Time
Constant
26-17
Term.
X42/1
Live
Zero
26-2*
Analog
Input
X42/3
26-20
Terminal
X42/3
Low
Voltage
26-21
Terminal
X42/3
High
Voltage
26-24
Term.
X42/3
Low
Ref./Feedb.
Value
26-25
Term.
X42/3
High
Ref./Feedb.
Value
26-26
Term.
X42/3
Filter
Time
Constant
26-27
Term.
X42/3
Live
Zero
26-3*
Analog
Input
X42/5
26-30
Terminal
X42/5
Low
Voltage
26-31
Terminal
X42/5
High
Voltage
26-34
Term.
X42/5
Low
Ref./Feedb.
Value
26-35
Term.
X42/5
High
Ref./Feedb.
Value
26-36
Term.
X42/5
Filter
Time
Constant
26-37
Term.
X42/5
Live
Zero
26-4*
Analog
Out
X42/7
26-40
Terminal
X42/7
Output
26-41
Terminal
X42/7
Min.
Scale
26-42
Terminal
X42/7
Max.
Scale
26-43
Terminal
X42/7
Bus
Control
26-44
Terminal
X42/7
Timeout
Preset
26-5*
Analog
Out
X42/9
26-50
Terminal
X42/9
Output
26-51
Terminal
X42/9
Min.
Scale
26-52
Terminal
X42/9
Max.
Scale
26-53
Terminal
X42/9
Bus
Control
26-54
Terminal
X42/9
Timeout
Preset
26-6*
Analog
Out
X42/11
26-60
Terminal
X42/11
Output
26-61
Terminal
X42/11
Min.
Scale
26-62
Terminal
X42/11
Max.
Scale
26-63
Terminal
X42/11
Bus
Control
26-64
Terminal
X42/11
Timeout
Preset
31-**
Bypass
Option
31-00
Bypass
Mode
31-01
Bypass
Start
Time
Delay
31-02
Bypass
Trip
Time
Delay
31-03
Test
Mode
Activation
31-10
Bypass
Status
Word
31-11
Bypass
Running
Hours
31-19
Remote
Bypass
Activation
35-**
Sensor
Input
Option
35-0*
Temp.
Input
Mode
35-00
Term.
X48/4
Temp.
Unit
35-01
Term.
X48/4
Input
Type
35-02
Term.
X48/7
Temp.
Unit
35-03
Term.
X48/7
Input
Type
35-04
Term.
X48/10
Temp.
Unit
35-05
Term.
X48/10
Input
Type
35-06
Temperature
Sensor
Alarm
Function
35-1*
Temp.
Input
X48/4
35-14
Term.
X48/4
Filter
Time
Constant
35-15
Term.
X48/4
Temp.
Monitor
35-16
Term.
X48/4
Low
Temp.
Limit
35-17
Term.
X48/4
High
Temp.
Limit
35-2*
Temp.
Input
X48/7
35-24
Term.
X48/7
Filter
Time
Constant
35-25
Term.
X48/7
Temp.
Monitor
35-26
Term.
X48/7
Low
Temp.
Limit
35-27
Term.
X48/7
High
Temp.
Limit
35-3*
Temp.
Input
X48/10
35-34
Term.
X48/10
Filter
Time
Constant
35-35
Term.
X48/10
Temp.
Monitor
35-36
Term.
X48/10
Low
Temp.
Limit
35-37
Term.
X48/10
High
Temp.
Limit
35-4*
Analog
Input
X48/2
35-42
Term.
X48/2
Low
Current
35-43
Term.
X48/2
High
Current
35-44
Term.
X48/2
Low
Ref./Feedb.
Value
35-45
Term.
X48/2
High
Ref./Feedb.
Value
35-46
Term.
X48/2
Filter
Time
Constant
35-47
Term.
X48/2
Live
Zero
99-*
Devel
support
99-00
DAC
1
selection
99-01
DAC
2
selection
99-02
DAC
3
selection
99-03
DAC
4
selection
99-04
DAC
1
scale
99-05
DAC
2
scale
99-06
DAC
3
scale
99-07
DAC
4
scale
99-08
Test
param
1
99-09
Test
param
2
99-10
DAC
Option
Slot
99-11
RFI
2
99-12
Fan
99-13
Idle
time
99-14
Paramdb
requests
in
queue
99-15
Secondary
Timer
at
Inverter
Fault
99-16
No
of
Current
Sensors
99-20
HS
Temp.
(PC1)
99-21
HS
Temp.
(PC2)
99-22
HS
Temp.
(PC3)
99-23
HS
Temp.
(PC4)
99-24
HS
Temp.
(PC5)
99-25
HS
Temp.
(PC6)
99-26
HS
Temp.
(PC7)
99-27
HS
Temp.
(PC8)
99-29
Platform
Version
99-40
StartupWizardState
99-90
Options
present
99-91
Motor
Power
Internal
99-92
Motor
Voltage
Internal
99-93
Motor
Frequency
Internal
99-94
Imbalance
derate
[%]
99-95
Temperature
derate
[%]
99-96
Overload
derate
[%]
Programming
VLT
®
HVAC Drive D-Frame
Operating Instructions
34
MG16D102 - VLT
®