Pin
No.
Schematic
acronym
Function
Description
Reading using a
digital voltmeter
1
IU1
Current sensed,
U phase, not
conditioned
Approx 400 mV RMS @100% load
.937 VACpeak @
165% of CT current
rating. AC waveform
@ output frequency
of the filter.
2
IV1
Current sensed,
V phase, not
conditioned
Approx 400 mV RMS @100% load
.937 VACpeak @
165% of CT current
rating. AC waveform
@ output frequency
of the filter.
3
IW1
Current sensed,
W phase, not
conditioned
Approx 400 mV RMS @100% load
.937 VACpeak @
165% of CT current
rating. AC waveform
@ output frequency
of the filter.
4
COMMON
Logic common
This common is for all signals.
5
Not used
6
Not used
7
INRUSH
Control Card
signal
Signal from the control card to start gating the SCR front end
3.3 V DC – Inrush
mode 0 V DC – Run
mode
8
Not used
9
Not used
10
Not used
11
VPOS
(+)18 V DC
regulated supply
(+)16.5 to 19.5 V
DC
The red LED indicates voltage is present between VPOS and VNEG
terminals.
(+)18 V DC regulated
supply (+)16.5 to 19.5
V DC
12
VNEG
(-) 18 V DC
regulated supply
(-) 16.5 to 19.5 V
DC
The red LED indicates voltage is present between VPOS and VNEG
terminals.
(-)18 V DC regulated
supply
(-)16.5 to 19.5 V DC
13
Not used
14
Not used
15
Not used
16
Not used
17
Not used
18
Not used