7.3.16 SCRs
1
2
3
4
5
6
7
8
9
10
12
13
14
15
11
130BX463.10
Figure 7.7 SCRs and IGBTs
1
SCR input bus bar
9
Snubber capacitor
2
0.4 in [10 mm] nut
10
T30 Screw
3
T30 screw
11
Round bus bar
support bracket
4
SCR
12
Current sensor
cylinder bus bar
5
IGBT output bus bar
13
T30 screw
6
IGBT module (1 of 3)
14
T30 screw
7
IGBT gate signal connector
15
T25 thread-forming
screw
8
IGBT thermal sensor
connector
Table 7.7 Legend to
1.
Remove the SCR input bus bars in accordance
with
chapter 7.3.15 SCR Input Bus Bars
2.
Remove the (+) DC bus bar SCR to DC coil by first
removing one screw (T30) that attaches the bus
bar to the DC inductor.
3.
Remove one screw (T30) from each SCR module.
For reassembly, use the replacement SCR instructions.
4.
Remove the Mylar insulator and retain it for
reassembly.
5.
Remove the (-) DC bus bar SCR to DC coil
following the same procedure as with the (+) DC.
6.
Disconnect the gate leads, one from each SCR
module.
7.
Remove one screw (T30) from either side of each
SCR module.
For reassembly, use the replacement SCR instructions.
7.3.17 Brake IGBT Module
3
4
5
1
2
130BC581.10
Figure 7.8 Brake IGBT module
1 T20 thread-forming screws
4 T30 screws
2 T25 thread-forming screw
5 Snubber capacitor
3 T25 screws
Table 7.8 Legend to
1.
Remove the IGBT gate drive board in accordance
with
chapter 7.3.14 IGBT Gate Drive Card
.
2.
Remove the line power terminal and motor
terminal in accordance with
and
.
3.
Remove the two brake to DC link bus bars in
accordance with
.
4.
Remove two thread-forming screws (T20) from
the top of the brake IGBT module.
5.
Remove the brake snubber capacitor by removing
two screws (T30), one from each bus bar.
Disassembly and Assembly In...
Service Manual
98
Danfoss A/S © Rev. 2014-02-10 All rights reserved.
MG94A222
7
7
Summary of Contents for VLT FC 103
Page 2: ......