4 Parameter Descriptions
4.1 Parameters: 0-** Operation and Display
Parameters related to the basic functions of the frequency
converter, function of the LCP keys, and configuration of
the LCP display.
4.1.1 0-0* Basic Settings
0-01 Language
Option:
Function:
Defines the language to be used in the display.
[0]
*
English
[10] Chinese
0-02 Motor Speed Unit
Option:
Function:
NOTICE
This parameter cannot be
adjusted while the motor is
running.
The information shown in the
display depends on settings in
parameter 0-02 Motor Speed Unit
.
The default settings of
parameter 0-02 Motor Speed Unit
depend on to which region of the
world the frequency converter is
supplied.
NOTICE
Changing the motor speed
unit resets certain parameters
to their initial value. Select the
motor speed unit before
modifying other parameters.
[0]
RPM
Select to show motor speed
variables and parameters using
motor speed (RPM).
[1]
*
Hz
Select to show motor speed
variables and parameters using
output frequency (Hz).
0-04 Operating State at Power-up (Hand)
Option:
Function:
Select the operating mode upon
reconnection of the frequency
converter to mains voltage after
power-down in hand-on mode.
0-04 Operating State at Power-up (Hand)
Option:
Function:
[0]
Resume
Restart the frequency converter,
maintaining the start/stop settings
(applied by [Hand On/Off]) selected
before power-down of the
frequency converter.
[1]
*
Forced stop,
ref=old
Restart the frequency converter
with a saved local reference after
mains voltage reappears and after
pressing [Hand On].
[2]
Forced stop,
ref=0
Reset the local reference to 0 upon
restarting the frequency converter.
4.1.2 0-1* Set-up Operations
Define and control the individual parameter set-ups.
The frequency converter has 4 parameter set-ups that can
be programmed independently of each other. This makes
the frequency converter very flexible and able to solve
advanced control functionality problems, often saving the
cost of external control equipment. Parameter set-ups can
be used to program the frequency converter to operate
according to 1 control scheme in 1 set-up (for example
motor 1 for horizontal movement) and another control
scheme in another set-up (for example motor 2 for vertical
movement). Alternatively, parameter set-ups can be used
by an OEM machine builder to identically program all their
factory-fitted frequency converters for different machine
types within a range to have the same parameters. During
production/commissioning, simply select a specific set-up
depending on which machine the frequency converter is
installed on.
The active set-up (that is the set-up in which the frequency
converter is currently operating) can be selected in
and is shown in the LCP. By
using multi set-up, it is possible to switch between set-ups
with the frequency converter running, or it can be stopped
via digital input or serial communication commands. If it is
necessary to change set-ups while the frequency converter
is running, ensure that
parameter 0-12 This Set-up Linked to
is programmed as required. By using
, it is possible to edit parameters within any of the
set-ups while continuing the operation of the frequency
converter in its active set-up, which can be a different set-
up to the one being edited. By using
, it is possible to copy parameter settings between the
set-ups to enable quicker commissioning if similar
parameter settings are required in different set-ups.
Parameter Descriptions
VLT® AutomationDrive FC 361
24
Danfoss A/S © 03/2019 All rights reserved.
MG06J202
4
4