7-92 Position PI Proportional Gain
Range:
Function:
value makes the control more dynamic
but less stable. 0=Off.
7-93 Position PI Integral Time
Range:
Function:
20000.0
ms
*
[1.0 -
20000.0 ms]
NOTICE
This parameter is only available
with software version 48.XX.
Enter the integral time for the
position PI controller. Decreasing the
value makes the control more
dynamic but less stable. 20000=Off.
7-94 Position PI Feedback Scale Numerator
Range:
Function:
1
*
[-2000000000
- 2000000000 ]
NOTICE
This parameter is only available with
software version 48.XX.
This parameter is the numerator in the
equation which defines the gear ratio
between the motor and the feedback device
when the feedback device is not mounted
on the motor shaft.
Encoder revolutions = Par . 7 − 94
Par . 7 − 95
× Motor revolutions
7-95 Position PI Feebback Scale Denominator
Range:
Function:
1
*
[-2000000000 -
2000000000 ]
NOTICE
This parameter is only available
with software version 48.XX.
See
.
7-97 Position PI Max Speed Above Master
Range:
Function:
100 RPM
*
[0 - 1500
RPM]
NOTICE
This parameter is only available
with software version 48.XX.
Enter the value by which the follower
speed is allowed to exceed the actual
master speed. Valid only in synchroni-
zation mode.
7-98 Position PI Feed Forward Factor
Range:
Function:
98 %
*
[0 - 110 %]
NOTICE
This parameter is only available with
software version 48.XX.
Enter the amount by which the speed
reference calculated by the profile generator
is allowed to bypass the position PI
controller.
7-99 Position PI Minimum Ramp Time
Range:
Function:
0.010 s
*
[0.000 -
3600.000 s]
NOTICE
This parameter is only available
with software version 48.XX.
Enter the shortest ramp time for the
output of the Position PI controller. Use
this parameter to limit acceleration
when correcting large position
deviations, for example when starting
synchronization with a running master
or after recovering from an overload
situation during positioning.
3.9 Parameters: 8-** Communications and
Options
NOTICE
Chapter 3.9 Parameters: 8-** Communications and Options
covers all the product series included in this
operating
guide
, but the options and parameter range may vary for
the different product series. For additional information,
consult the product-specific
programming guide
.
3.9.1 8-0* General Settings
8-01 Control Site
The setting in this parameter overrides the settings in
parameter 8-50 Coasting Select
to
parameter 8-56 Preset Reference
.
Option:
Function:
[0]
*
Digital and ctrl.word
Use both digital input and
control word.
[1]
Digital only
Use digital inputs only.
[2]
Controlword only
Use control word only.
Parameter Descriptions