4.1.9 8-** Comm. and Options
Param-
eter #
Parameter description
Default value
4 set-up
Change during
operation
Conversion
index
Type
8-0* General Settings
8-01
Control Site
[0] Digital and
ctrl.word
All set-ups
TRUE
-
Uint8
8-02
Control Source
ExpressionLimit
All set-ups
TRUE
-
Uint8
8-03
Control Timeout Time
ExpressionLimit
1 set-up
TRUE
-1
Uint32
8-04
Control Timeout Function
[0] Off
1 set-up
TRUE
-
Uint8
8-05
End-of-Timeout Function
[1] Resume set-up
1 set-up
TRUE
-
Uint8
8-06
Reset Control Timeout
[0] Do not reset
All set-ups
TRUE
-
Uint8
8-07
Diagnosis Trigger
[0] Disable
2 set-ups
TRUE
-
Uint8
8-08
Readout Filtering
ExpressionLimit
All set-ups
TRUE
-
Uint8
8-1* Control Settings
8-10
Control Profile
[0] FC profile
All set-ups
TRUE
-
Uint8
8-13
Configurable Status Word STW
[1] Profile Default
All set-ups
TRUE
-
Uint8
8-14
Configurable Control Word CTW
[1] Profile default
2 set-ups
TRUE
-
Uint8
8-17
Configurable Alarm and
Warningword
[0] Off
All set-ups
TRUE
-
Uint16
8-3* FC Port Settings
8-30
Protocol
[0] FC
1 set-up
TRUE
-
Uint8
8-31
Address
ExpressionLimit
1 set-up
TRUE
0
Uint8
8-32
Baud Rate
ExpressionLimit
1 set-up
TRUE
-
Uint8
8-33
Parity/Stop Bits
ExpressionLimit
1 set-up
TRUE
-
Uint8
8-35
Minimum Response Delay
10 ms
1 set-up
TRUE
-3
Uint16
8-36
Max Response Delay
ExpressionLimit
1 set-up
TRUE
-3
Uint16
8-37
Maximum Inter-Char Delay
ExpressionLimit
1 set-up
TRUE
-5
Uint16
8-4* FC MC protocol set
8-40
Telegram Selection
[1] Standard
telegram 1
2 set-ups
TRUE
-
Uint8
8-42
PCD Write Configuration
ExpressionLimit
2 set-ups
TRUE
-
Uint16
8-43
PCD Read Configuration
ExpressionLimit
2 set-ups
TRUE
-
Uint16
8-5* Digital/Bus
8-50
Coasting Select
[3] Logic OR
All set-ups
TRUE
-
Uint8
8-51
Quick Stop Select
[4] Disabled
All set-ups
TRUE
-
Uint8
8-52
DC Brake Select
ExpressionLimit
All set-ups
TRUE
-
Uint8
8-53
Start Select
[3] Logic OR
All set-ups
TRUE
-
Uint8
8-54
Reversing Select
[0] Digital input
All set-ups
TRUE
-
Uint8
8-55
Set-up Select
[3] Logic OR
All set-ups
TRUE
-
Uint8
8-56
Preset Reference Select
[3] Logic OR
All set-ups
TRUE
-
Uint8
8-7* BACnet
8-70
BACnet Device Instance
1 N/A
1 set-up
TRUE
0
Uint32
8-72
MS/TP Max Masters
127 N/A
1 set-up
TRUE
0
Uint8
8-73
MS/TP Max Info Frames
1 N/A
1 set-up
TRUE
0
Uint16
8-74
"I-Am" Service
[0] Send at power-
up
1 set-up
TRUE
-
Uint8
8-75
Initialisation Password
ExpressionLimit
1 set-up
TRUE
0
VisStr[20]
8-8* FC Port Diagnostics
8-80
Bus Message Count
0 N/A
All set-ups
TRUE
0
Uint32
8-81
Bus Error Count
0 N/A
All set-ups
TRUE
0
Uint32
8-82
Slave Message Rcvd
0 N/A
All set-ups
TRUE
0
Uint32
8-83
Slave Error Count
0 N/A
All set-ups
TRUE
0
Uint32
8-9* Bus Jog/Feedback
Parameter Lists
VLT
®
AQUA Drive FC 202
260
Danfoss A/S © 05/2018 All rights reserved.
MG20OB02
4