3.1.3 Ordering Form type code
130BB504.10
1
2 3
4
5
6 7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39
A F
A
x
0 0
A
T
4
E
H
x
G C
x
x
x
x
x
x
x
B x
C x
x
x
x
x
D
A
S
Possible choice
Product groups
1-3
AAF
Series
4-6
005
Current rating
7-10
A190: 190Amp
A250: 250Amp
Phases
11
T: Three Phases
AC Line Voltage
12
4: 380–480V AC
enclosure
13-15
E21: IP21/Nema Type1
ESH: IP54 hybrid
RFI filter
16-17
H2: RFI filter, Class A2
(standard)
H4: RFI filter, Class A1 (optional)
Display (LCP)
19
G: Graphical Local Control
Panel (LCP)
Coating PCB
20
C: Coated PCB
Line power option
21
X: No AC line option
3: Line power disconnect and
fuse
7: Fuse
Adaptation A
22
Reserved
Adaptation B
23
Reserved
Software release
24-27
Reserved
Software language
28
Reserved
A options
29-30
AX: No A option
B options
31-32
BX: No B option
C option configu-
ration
33-37
CFxxx: CO option occupied
with active filter control card
D options
38-39
DX: No Options
Possible choice
Product groups
1-3
AAF
Series
4-6
006
Current rating
7-10
A190: 190Amp
A250: 250Amp
A310: 310Amp
A400: 400 Amp
Phases
11
T: Three Phases
AC Line Voltage
12
4: 380–480V AC
enclosure
13-15
E21: IP21/Nema Type1
E54: IP54/Nema Type 12
E2M: IP21/Nema Type 1 with line
power shield
E5M: IP54/Nema Type 12 with
line power shield
RFI filter
16-17
H2: RFI filter, Class A2 (standard)
H4: RFI filter, Class A1 (optional)
Display (LCP)
19
G: Graphical Local Control Panel
(LCP)
Coating PCB
20
C: Coated PCB
Line power option 21
X: No AC line option
3: Line power disconnect and
fuse
7: Fuse
Adaptation A
22
Reserved
Adaptation B
23
Reserved
Software release
24-27
Reserved
Software language 28
Reserved
A options
29-30
AQ: MCA-122 Modbus TCP
AX: No A option
B options
31-32
BX: No B option
C option configu-
ration
33-37
CFxxx: CO option occupied with
active filter control card
D options
38-39
DO: 24V backup
DX: No Options
Introduction to VLT Active ...
VLT Active Filter AAF 00x
MG.90.V2.22 - VLT
®
is a registered Danfoss trademark
3-3
3
3