Status Messages
Status messages appear in the 4th line of the
display, see the example.
The left part of the status line indicates the active type
of control of the VLT 500 Crane. The right part states
the present status, eg. "Running", "Stop", "Coast", etc.
SETUP
1
STOP
RAMPING
LOCAL
80.0% 5.08A
40.0Hz
REMOTE RUNNING
Left part:
Crane:
The drive profile for the frequency converter
is Crane profile (Parameter 512)
Rem:
Remote has been selected in parameter 002,
the reference is set via the control terminal or via
the serial communication. The drive profile for the
frequency converter is FC-profile (parameter 512)
Local:
Local has been selected in parameter
002, the reference is set in parameter 003.
The drive profile for the frequency converter
is FC-profile (parameter 512)
Right part:
Ramping:
The output frequency is now changed
according to the present ramp
Coast:
The motor has been coasted
via a coast signal
Qstop:
The motor has been stopped
via a qstop signal
Stop:
The motor has been stopped via a stop signal
Stand by:
The frequency converter will start
when it receives a start signal via digital input
or the serial communication port.
Run jog:
Jog has been enabled via LCP digital
input or the serial communication port.
Running:
The motor speed corresponds
to the resulting reference
Br. Error: Stop:
A brake release error has been
detected and the motor is coasted.
Br. Error: Low:
A brake activate error has been
detected and the frequency converter is lowering.