VLT® 5000 Crane
Installation
33: Load high (NO)
37: Hardware coast (NC)
39: Ground for analogue/digital outputs
42: Analogue output warning/alarm
45: Analogue output warning/alarm
46: Digital output
50: 10 V supply
53: Reference voltage
55: Common for anal. ref.
60: Reference current
68, 69: RS 485
01, 02: System brake signal
04, 05: Ready signal
73: Pulse signal A from encoder (0°)
74: Inverted pulse signal from encoder (0°)
75: Pulse signal B from encoder (90°)
76: Inverted pulse signal B from encoder (90°)
77: Zero pulse signal from encoder
78: Inverted zero pulse signal from encoder
49: 5 V supply to encoder
47: Common for encoder supply
■
Electrical Installation, Power Cables
Compact IP 20 VLT Type 5042–5062
Compact IP 20/IP 00 VLT Types 5072-5102
Compact IP 00 VLT 5125-5250 400-500 V
■
Connection of Mains
Connect the three mains phases to terminals L
1
, L
2
, L
3
.
■
Connection of Motor
All types of 3-phased asynchronous standard motors
can be used with the VLT 5000 Crane.