VLT® 5000/ 5000 FLUX/ 6000 HVAC/
8000 AQUA PROFIBUS
Parameter list VLT 5000
PNU
Parameter
Factory setting
Range
Changes
4-Setup
Conversion
Data
#
description
during operation
index
type
001
L
L
L
La
a
a
an
n
n
ng
g
g
gu
u
u
ua
a
a
ag
g
g
ge
e
e
e
English
Yes
No
0
5
002
L
L
L
Lo
o
o
oc
c
c
ca
a
a
allll////rrrre
e
e
em
m
m
mo
o
o
otttte
e
e
e c
c
c
co
o
o
on
n
n
nttttrrrro
o
o
ollll
Remote control
Yes
Yes
0
5
003
L
L
L
Lo
o
o
oc
c
c
ca
a
a
allll rrrre
e
e
effffe
e
e
errrre
e
e
en
n
n
nc
c
c
ce
e
e
e
000.000
Yes
Yes
-3
4
004
A
A
A
Ac
c
c
cttttiiiiv
vv
ve
e
e
e s
ss
se
e
e
ettttu
u
u
up
p
p
p
Setup 1
Yes
No
0
5
005
P
P
P
Prrrro
o
o
og
g
g
grrrra
a
a
am
m
m
mm
m
m
miiiin
n
n
ng
g
g
g s
ss
se
e
e
ettttu
u
u
up
p
p
p
Active setup
Yes
No
0
5
006
C
C
C
Co
o
o
op
p
p
py
yy
yiiiin
n
n
ng
g
g
g o
o
o
offff s
ss
se
e
e
ettttu
u
u
up
p
p
ps
ss
s
No copying
No
No
0
5
007
L
L
L
LC
C
C
CP
P
P
P c
c
c
co
o
o
op
p
p
py
yy
y
No copying
No
No
0
5
008
D
D
D
Diiiis
ss
sp
p
p
plllla
a
a
ay
yy
y s
ss
sc
c
c
ca
a
a
alllliiiin
n
n
ng
g
g
g o
o
o
offff m
m
m
mo
o
o
otttto
o
o
orrrr ffffrrrre
e
e
eq
q
q
qu
u
u
ue
e
e
en
n
n
nc
c
c
cy
yy
y 1
0.01 - 500.00
Yes
Yes
-2
6
009
D
D
D
Diiiis
ss
sp
p
p
plllla
a
a
ay
yy
y lllliiiin
n
n
ne
e
e
e 2
2
2
2
Frequency [Hz]
Yes
Yes
0
5
010
D
D
D
Diiiis
ss
sp
p
p
plllla
a
a
ay
yy
y lllliiiin
n
n
ne
e
e
e 1
1
1
1....1
1
1
1
Reference [%]
Yes
Yes
0
5
011
D
D
D
Diiiis
ss
sp
p
p
plllla
a
a
ay
yy
y lllliiiin
n
n
ne
e
e
e 1
1
1
1....2
2
2
2
Motor current [A]
Yes
Yes
0
5
012
D
D
D
Diiiis
ss
sp
p
p
plllla
a
a
ay
yy
y lllliiiin
n
n
ne
e
e
e 1
1
1
1....3
3
3
3
Power [kW]
Yes
Yes
0
5
013
L
L
L
Lo
o
o
oc
c
c
ca
a
a
allll c
c
c
co
o
o
on
n
n
nttttrrrro
o
o
ollll////c
c
c
co
o
o
on
n
n
nffffiiiig
g
g
gu
u
u
urrrra
a
a
a
LCP digital control/as
par.100
Yes
Yes
0
5
014
L
L
L
Lo
o
o
oc
c
c
ca
a
a
allll s
ss
stttto
o
o
op
p
p
p
Possible
Yes
Yes
0
5
015
L
L
L
Lo
o
o
oc
c
c
ca
a
a
allll jjjjo
o
o
og
g
g
g
Not possible
Yes
Yes
0
5
016
L
L
L
Lo
o
o
oc
c
c
ca
a
a
allll rrrre
e
e
ev
vv
ve
e
e
errrrs
ss
siiiin
n
n
ng
g
g
g
Not possible
Yes
Yes
0
5
017
L
L
L
Lo
o
o
oc
c
c
ca
a
a
allll rrrre
e
e
es
ss
se
e
e
etttt o
o
o
offff ttttrrrriiiip
p
p
p
Possible
Yes
Yes
0
5
018
L
L
L
Lo
o
o
oc
c
c
ck
k
k
k ffffo
o
o
orrrr d
d
d
da
a
a
atttta
a
a
a c
c
c
ch
h
h
ha
a
a
an
n
n
ng
g
g
ge
e
e
e
Not locked
Yes
Yes
0
5
019
O
O
O
Op
p
p
pe
e
e
errrra
a
a
attttiiiin
n
n
ng
g
g
g s
ss
stttta
a
a
atttte
e
e
e a
a
a
atttt p
p
p
po
o
o
ow
w
w
we
e
e
errrr----u
u
u
up
p
p
p,,,, llllo
o
o
oc
c
c
ca
a
a
allll
c
c
c
co
o
o
on
n
n
nttttrrrro
o
o
ollll
Forced stop, use
saved ref.
Yes
Yes
0
5
027
W
W
W
Wa
a
a
arrrrn
n
n
niiiin
n
n
ng
g
g
g rrrre
e
e
ea
a
a
ad
d
d
do
o
o
ou
u
u
utttt
Warning in line 1/2
Yes
No
0
5
Changes during operation:
"Yes" means that the parameter can be changed,
while the frequency converter is in operation. "No"
means that the frequency converter must be stopped
before a change can be made.
4-Setup:
"Yes" means that the parameter can be programmed
individually in each of the four setups, i.e. the
same parameter can have four different data
values. "No" means that the data value will be
the same in all four setups.
Conversion index:
This number refers to a conversion figure to
be used when writing or reading by means
of a frequency converter.
Conversion index
Conversion factor
74
0.1
2
100
1
10
0
1
-1
0.1
-2
0.01
-3
0.001
-4
0.0001
Data type:
Data type shows the type and length of the telegram.
Data type
Description
3
Integer 16
4
Integer 32
5
Unsigned 8
6
Unsigned 16
7
Unsigned 32
9
Text string