External reference [%]
gives the sum of external refer-
ences as a percentage (sum of analogue/pulse/serial
communication) in the range from Minimum reference,
Ref
MIN
to Maximum reference, Ref
MAX
.
Status word [Hex]
gives one or several status condi-
tions in a Hex code. See
Serial communication
in
the
Design Guide
for further information.
Heatsink temp.[°C]
gives the present heatsink temper-
ature of the frequency converter. The cut-out limit is
90-100°C, while cutting back in occurs at 70 ± 5°C.
Alarm word [Hex]
gives one or several alarms in hex
code. See
Serial communication
in the
Design Guide
for
further information.
Control word [Hex]
gives the control word for the fre-
quency converter. See
Serial communication
in the
Design Guide
for further information.
Warning word [Hex]
gives one or several warnings in
hex code. See
Serial communication
in the
Design
Guide
for further information.
Extended status word [Hex]
gives one or several status
modes in Hex code. See
Serial communication
in the
Design Guide
for further information.
Communication option card warning [Hex]
gives a
warning word if there is a fault in the communication
bus. Only active if communication options are instal-
led.
If there are no communication options 0 Hex is dis-
played.
Pulse count
gives the number of pulses that the unit
has registered.
Power [W]
gives the present power that the motor is
absorbing in W.
010
Small display line 1.1
(DISPLAY LINE 1.1)
Value:
See par. 009
Large dis-
play readout
Analog input 53 [V]
[17]
Function:
In this parameter, the first of three data values can be
selected that is to be displayed in the LCP control unit
display, line 1, position 1. This is a useful function, e.g.
when setting the PID regulator, as it gives a view of
process reactions to reference changes. The display
readout is activated by pushing the [DISPLAY STA-
TUS] key.
Description of choice:
See parameter 009
Large display readout
.
011
Small display readout 1.2
(DISPLAY LINE 1.2)
Value:
See parameter 009
Large
display readout
Motor current [A][6]
Function:
See the functional description given under parameter
010
Small display readout
.
Description of choice:
See parameter 009
Large display readout
.
012
Small display readout 1.3
(DISPLAY LINE 1.3)
Value:
See parameter 009
Large
display readout
Feedback [unit] [3]
Function:
See the functional description given under parameter
010
Small display readout
.
Description of choice:
See parameter 009
Large display readout
.
013
Local control
(LOC CTRL/CONFIG.)
Value:
Local not active (DISABLE)
[0]
Local control and open loop without slip com-
pensation
(LOC CTRL/OPEN LOOP)
[1]
Remote-operated control and open loop with-
out slip compensation
(LOC+DIG CTRL)
[2]
Local control as parameter 100
(LOC CTRL/AS P100)
[3]
Remote-operated control as parameter 100
(LOC+DIG CTRL/AS P100)
[4]
Function:
This is where the required function is selected if, in
parameter 002
Local/remote operation, Local opera-
tion
[1] has been chosen.
= factory setting, () = display text, [] = value for use in communication via serial communication port
MG.27.E2.02 - VLT is a registered Danfoss trademark
63