background image

Parameter

 Overwiev

0-XX

 Operation/Display

0-01

 Language

*[0]

 English

[1]

 German

[2]

 French

[3]

 Danish

[4]

 Spanish

[5]

 Italian

002

 Local/Remote

 Operation

*[0]

 Remote

 operation

[1]

 Local

 operation

003

 Local

 Reference

If 

par.

 013

 =

 [1]

 or

 [2]:

 0

 -

 f

MAX

, *50

 Hz

If 

par.

 013

 =

 [3]

 or

 [4]:

 Ref

MIN

 -

 Ref

MAX

, *0.0

004

 Active

 Set-up

[0]

 Factory

 Set-up

*[1]

 Set-up

 1

[2]

 Set-up

 2

[3]

 Set-up

 3

[4]

 Set-up

 4

[5]

 Multi

 Set-up

005

 Programming

 Set-up

[0]

 Factory

 Set-up

*[1]

 Set-up

 1

[2]

 Set-up

 2

[3]

 Set-up

 3

[4]

 Set-up

 4

*[5]

 Active

 Set-up

0-06

 Set-up

 Copying

*[0]

 No

 copying

[1]

 Copy

 to

 Set-up

 1

 from

 #

[2]

 Copy

 to

 Set-up

 2

 from

 #

[3]

 Copy

 to

 Set-up

 3

 from

 #

[4]

 Copy

 to

 Set-up

 4

 from

 #

[5]

 Copy

 to

 all

 set-ups

 from

 #

007

 LCP

 Copy

*[0]

 No

 copying

[1]

 Upload

 all

 parameters

[2]

 Download

 all

 parameters

[3]

 Download

 size-independent

 parameters

008

 Display

 Scaling

 of

 Output

 Frequency

0.01

 -

 100.00,

 *1.00

009

 Large

 Diplay

 Readout

[0]

 No

 readout

[1]

 Resulting

 reference

 [%]

[2]

 Resulting

 reference

 [unit]

[3]

 Feedback

 [unit]

*[4]

 Frequency

 [Hz]

[5]

 Output

 frequency

 x

 scaling

[6]

 Motor

 current

 [A]

[7]

 Torque

 [%]

[8]

 Power

 [kW]

[9]

 Power

 [HP]

[11]

 Motor

 voltage

 [V]

[12]

 DC

 link

 voltage

 [V]

[13]

 Thermal

 load

 motor

 [%]

[14]

 Thermal

 load

 [%]

[15]

 Running

 hours

 [Hours]

[16]

 Digital

 input

 [Bin]

[17]

 Analog

 input

 53

 [V]

[19]

 Analog

 input

 60

 [mA]

[20]

 Pulse

 reference

 [Hz]

[21]

 External

 reference

 [%]

[22]

 Status

 word

 [Hex]

[25]

 Heatsink

 temperature

 [

°

C]

[26]

 Alarm

 word

 [Hex]

[27]

 Control

 word

 [Hex]

[28]

 Warning

 word

 [Hex]

[29]

 Extended

 status

 word

 [Hex]

[30]

 Communication

 option

 card

 warning

[31]

 Pulse

 count

010

 Small

 Display

 Line

 1.1

See

 par.

 009.

*[17]

 Analog

 input

 53

011

 Small

 Display

 Readout

 1.2

See

 par.

 009.

*[6]

 Motor

 Current

 [A]

012

 Small

 Display

 Readout

 1.3

*See

 par.

 009.

*[3]

 Feedback

 [unit]

013

 Local

 Control

[0]

 Local

 not

 active

[1]

 Local

 control

 and

 open

 loop

 without

 slip

compensation [2]

 Remote-operated

 control

 and

 open

 loop

 without

slip

 compensation

[3]

 Local

 control

 as

 par.

 100

*[4]

 Remote-operated

 contorl

 as

 par.

 100

014

 Local

stop

[0]

 Not

 active

*[1]

 Active

015

 Local

 Jog

*[0]

 Not

 active

[1]

 Active

016

 Local

 Reversing

*[0]

 Not

 active

[1]

 Active

017

 Local

 reset

 of

 Trip

[0]

 Not

 active

*[1]

 Active

018

 Lock

 for

 Data

 Changes

*[0]

 Not

 locked

[1]

 Locked

019

 Operating

 Mode

 at

 Power-up,

 Local

 Operation

[0]

 Auto

 re-start,

 use

 saved

 reference

*[1]

 Forced

 stop,

 use

 saved

 reference

[2]

 Forced

 stop,

 set

 ref.

 to

 0

020

 Hand

 Operation

*[0]

 Not

 active

[1]

 Active

024

 Userdefined

 Quick

 Menu

*[0]

 Not

 active

[1]

 Active

025

 Quick

 Menu

 Set-up

Value

 0

 -

 999,

 *000

Load

 and

 Motor

100

 Configuration

*[0]

 Speed

 control,

 open

 loop

[2]

 Speed

 control,

 closed

 loop

[3]

 Process

 control,

 closed

 loop

101

 Torque

 Characteristic

*[1]

 Constant

 torque

[2]

 Variable

 torque

 low

[3]

 Variable

 torque

 medium

[4]

 Variable

 torque

 high

[5]

 Variable

 torque

 low

 with

 CT

 start

[6]

 Variable

 torque

 medium

 with

 CT

 start

[7]

 Variable

 torque

 high

 with

 CT

 start

[8]

 Special

 motor

 mode

102

 Motor

 Power

 P

M,N

0.25

 -

 22

 kW,

 *Dep.

 on

 unit

103

 Motor

 Voltage

 U

M,N

For

 200

 V

 units:

 50

 -

 999

 V,

 *230

 V

For

 400

 V

 units:

 50

 -

 999

 V,

 *400V

104

 Motor

 Frequency

 f

M,N

24

 -

 1000

 Hz,

 *50

 Hz

105

 Motor

 Current

 I

M,N

0.01

 -

 I

MAX

, Dep.

 on

 motor

106

 Rated

 Motor

 Speed

100

 -

 f

M,N

 x

 60

 (max.

 60000

 rpm),

 Dep.

 on

 par.

 104

107

 Automatic

 Motor

 Tuning,

 AMT

*[0]

 Optimisation

 off

[1]

 Optimisation

 on

108

 Stator

 Resistance

 R

S

0.000

 -

 x.xxx

 

Ω

, *Dep.

 on

 motor

109

 Stator

 Resistance

 X

S

0.00

 -

 x.xx

 

Ω

, *Dep.

 on

 motor

117

 Resonance

 Damping

OFF

 -

 100%

*OFF%

119

 High

 Start

 Torque

0.0

 -

 0.5

 s

 *

 0.0

 s

120

 Start

 Delay

0.0

 -

 10.0

 s

 *

 0.0

 s

Control Panel Operations

Quick Guide

MG28M202

Danfoss A/S © Rev. 2014-03-18 All rights reserved.

21

5

5

Summary of Contents for VLT 2800

Page 1: ...MAKING MODERN LIVING POSSIBLE Quick Guide VLT 2800 www danfoss com drives...

Page 2: ......

Page 3: ...ables 9 4 Electrical Installation 10 4 1 Electrical Installation in General 10 4 2 Power Cables 10 4 3 Mains Connection 12 4 4 Motor Connection 12 4 5 Parallel Connection of Motors 12 4 6 Motor Cables...

Page 4: ...27 7 1 1 Mains Supply 200 240 V 27 7 1 2 Mains Supply 380 480 V 27 7 2 General Specifications 28 7 3 Special Conditions 32 7 3 1 Aggressive Environments 32 7 3 2 Derating for Ambient Temperature 32 7...

Page 5: ...are available to understand advanced frequency converter functions and programming VLT 2800 Design Guide VLT 2800 Filter Instruction Brake Resistor Manual Profibus DP V1 Manual Profibus DP Manual VLT...

Page 6: ...nce must be performed by qualified personnel only WARNING UNINTENDED START When the frequency converter is connected to AC mains DC power supply or load sharing the motor may start at any time Uninten...

Page 7: ...the procedures in this manual CAUTION INTERNAL FAILURE HAZARD An internal failure in the frequency converter can result in serious injury when the frequency converter is not properly closed Before app...

Page 8: ...with enclosure IP20 must be integrated in cabinets and panels IP20 is not suitable for remote mounting In some countries for example in the USA units with enclosure NEMA 1 are approved for remote moun...

Page 9: ...AC VLT 2805 2815 200 191 75 60 168 7 5 4 5 8 4 4 5 VLT 2822 2840 267 5 257 90 70 168 8 6 5 5 11 4 5 5 5 VLT 2855 2875 267 5 257 140 120 168 8 6 5 5 11 4 5 5 5 VLT 2880 2882 505 490 200 120 244 7 75 7...

Page 10: ...IP21 Solution Type Code number A B C VLT 2803 2815 200 240 V VLT 2805 2815 380 480 V 195N2118 47 80 170 VLT 2822 200 240 V VLT 2822 2840 380 480 V 195N2119 47 95 170 VLT 2840 200 240 V VLT 2822 PD2 VL...

Page 11: ...b J K L M N 75 45 6 190 60 16 24 12 192H4720 A B C a D E F G 20 273 20 5 5 8 303 25 313 H I b J K L M N 90 50 6 257 70 16 24 12 192H4893 A B C a D E F G 20 273 20 5 5 8 303 25 313 H I b J K L M N 140...

Page 12: ...Nm Torque Control Cables Nm 2803 2875 Power mains brake 0 5 0 6 0 22 0 25 Ground 2 3 2880 2882 2840 PD2 Power mains brake 1 2 1 5 Ground 2 3 4 2 Power Cables NOTICE The power terminals can be removed...

Page 13: ...5 VLT 2840 200 240 V PD2 VLT 2880 2882 380 480 V Illustration 4 6 Electrical Connections VLT 2880 2882 and 2840 PD2 Fit screened armoured cable from the motor to the motor terminals of the frequency...

Page 14: ...n in the VLT 2800 Design Guide for further details 4 4 Motor Connection Connect the motor to terminals 96 97 98 Connect ground to terminal 99 See chapter 7 2 General Specifications for correct dimensi...

Page 15: ...lator or motor relay the screen must be continued at the lowest possible HF impedance 4 7 Motor Thermal Protection The electronic thermal relay in the frequency converter has received the UL approval...

Page 16: ...ket for the relay must cover the first row of control card terminals otherwise the galvanic isolation PELV cannot be maintained Max cable diameter 4 mm 4 9 Grounding Comply with the following at insta...

Page 17: ...borne 150 kHz 30 MHz Radiated 30 MHz 1 GHz Cable borne 150 kHz 30 MHz Radiated 30 MHz 1GHz 3 x 480 V version with 1B RFI filter Yes 50 m Yes 50 m Yes 50 m No Table 4 6 EMC Emission Compliance 1 For VL...

Page 18: ...ood electrical contact from the installation plate through the installation screws to the metal cabinet of the frequency converter Use starwashers and galvanically conductive installation plates Do no...

Page 19: ...JDDZ RK1 JDDZ 2805 2820 KTS R20 JKS 20 JJS 20 FNQ R 20 KTK R 20 LP CC 20 5017906 0 20 KLS R20 ATM R25 A6K 20R 2855 2875 KTS R25 JKS 25 JJS 25 5017906 0 25 KLS R25 ATM R20 A6K 25R 2880 2882 KTS R50 JK...

Page 20: ...3 digits To see the value press CHANGE DATA The CHANGE DATA key is also used for confirming a change of parameter settings are used for selecting parameters and for changing parameter values These ke...

Page 21: ...er is in Auto mode where the reference signal is given externally analog or digital via the control terminals However in Hand mode it is possible to give the reference signal locally via the control p...

Page 22: ...rence 5 2 Motor Start Press START to start the motor Set the motor speed by adjusting parameter 003 Local Reference Check whether the direction of rotation of the motor shaft is clockwise If not excha...

Page 23: ...eedback unit 013 Local Control 0 Local not active 1 Local control and open loop without slip compensation 2 Remote operated control and open loop without slip compensation 3 Local control as par 100 4...

Page 24: ...0 000 Hz Par 100 1 3 Par 204 Ref MIN Par 415 Max Feedback 50 000 rpm par 416 206 Ramp Type 0 Linear 1 Sin shaped 2 Sin 2 207 Ramp up Time 1 0 02 3600 00 s 3 00 s VLT 2803 2875 10 00 2880 2882 208 Ramp...

Page 25: ...min max 0 20 mA 2 External reference min max 4 20 mA 3 Feedback min max 0 20 mA 4 Feedback min max 4 20 mA 5 Output frequency 0 max 0 20 mA 6 Output frequency 0 max 4 20 mA 7 Output current 0 I INV 0...

Page 26: ...428 F3 frequency par 104 427 U3 Voltage 0 0 999 0 V par 103 428 F3 Frequency Par 426 F2 frequency 1000 Hz par 104 437 Process PID Normal Inverse Control 0 Normal 1 Inverse 438 Process PID Anti Windup...

Page 27: ...T X X Short circuit on the motor terminals or in the motor 17 Serial communication timeout STD BUS TIMEOUT X X No serial communication to the frequency converter 18 HPFB bus timeout HPFB TIMEOUT X X N...

Page 28: ...in 3 ways 1 Via the operating key STOP RESET 2 Via a digital input 3 Via serial communication It is also possible to select an automatic reset in parameter 405 Reset function When a cross appears in b...

Page 29: ...ency 95 95 95 95 95 95 95 95 95 Power loss at 100 load W 24 35 48 69 94 125 125 231 231 Weight kg 2 0 2 0 2 0 2 0 2 0 3 7 6 0 6 0 18 5 Enclosure type IP 20 IP 20 IP 20 IP 20 IP 20 IP 20 IP 20 IP 20 IP...

Page 30: ...0 Supply voltage VLT 2805 2840 R5 380 400 V 10 Supply frequency 50 60 Hz 3 Hz Max imbalance on supply voltage 2 0 of rated supply voltage True Power Factor 0 90 nominal at rated load Displacement Powe...

Page 31: ...ccuracy of analog inputs Max error 1 of full scale Scan interval 13 3 m The analog inputs are galvanically isolated from the supply voltage PELV and other high voltage terminals See section Galvanic I...

Page 32: ...lly isolated from the supply voltage PELV but has the same potential as the analogue and digital inputs and outputs See section Galvanic Isolation in the Design Guide Control card 10 V DC output Termi...

Page 33: ...speed Speed control range closed loop 1 120 of synchronous speed Speed accuracy open loop 150 3600 RPM Max error of 23 RPM Speed accuracy closed loop 30 3600 RPM Max error of 7 5 RPM All control char...

Page 34: ...s on existing electrical installations 7 3 2 Derating for Ambient Temperature The ambient temperature measured over 24 hours should be at least 5 C lower than the max ambient temperature If the freque...

Page 35: ...I IT mains 17 L Leakage current 5 M Mains connection 12 Mechanical installation 6 Menu mode 19 Motor cable 13 Motor coil 7 Motor connection 12 Motor thermal protection 13 Motors parallel connection 1...

Page 36: ...to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed All trademarks in this material are property of...