Code
Description
NXP
The product range:
•
NXP = VACON
®
NXP
•
NXS = VACON
®
NXS
0003
The drive rating in amperes. For example, 0003 = 3 A
5
The mains voltage:
•
2 = 208–240 V
•
5 = 380–500 V
•
6 = 525–600 V (IEC)
525–600 V (cULus)
A
The control panel:
•
A = standard (text display)
•
B = no local control panel
•
F = dummy keypad
•
G = graphic display
2
The protection rating:
•
0 = IP00
•
2 = IP21 (UL Type 1)
•
5 = IP54 (UL Type 12)
•
T = flange-mounted (through-hole mounted)
H
The EMC emission level:
•
C = complies with the category C1 of standard IEC/EN 61800-3 + A1, 1st environment, and nominal voltage less
than 1000 V
•
H = complies with the category C2 of standard IEC/EN 61800-3 + A1, fixed installations, and nominal voltage
less than 1000 V
•
L = complies with the category C3 of standard IEC/EN 61800-3 + A1, 2nd environment, and nominal voltage less
than 1000 V
•
T = complies with the standard IEC/EN 61800-3 + A1 when used in IT networks (C4).
•
N = No EMC emission protection. An external EMC filter is necessary.
1
The brake chopper:
(1)
•
0 = No brake chopper
•
1 = Internal brake chopper
•
2 = Internal brake chopper and resistor, available for:
-
208–240 V (FR4–FR6)
-
380–500 V (FR4–FR6)
Product Overview
Operating Guide | VACON® NXS/NXP Air-cooled
AQ275638903263en-000301 / DPD00910
18 | Danfoss A/S © 2020.02