Compressor Components
1. Apply a thin layer of heat sink paste to the
bottom of the SCRs.
2. Install the SCRs to the cooling manifold.
3. Install the DC bus and snubber capacitors. See
Figure 38.
4. Install the AC Mains Input bus bars. See Figure
35 (SCR Connections).
5. Install the Soft Start cable harness and Soft
Start.
6. Using needle-nose pliers, carefully install the
SCR gate cable harness to the SCRs.
7. Install the topside covers.
1. Install the SCR temperature sensor into the SCR
manifold.
2. (TT300/TG230 Only) Lift the SCR manifold and
route the SCR temperature sensor cable under
the SCR manifold.
3. (TT300/TG230 Only) Tighten the Inverter
manifold screws.
4. Connect the SCR temperature sensor
connector to the cable harness.
5. Install the DC bus and snubber capacitors. See
Figure 38 (DC Bus Components Identification).
6. Install the terminal block and AC Mains Input
bus bars. See Figure 35 (SCR Connections).
7. Install the Soft Start Cable Harness and Soft
Start.
8. Using needle-nose pliers, carefully install the
SCR gate cable harness to the SCRs.
9. Install the topside covers.
3.5.4.3 SCR Installation
3.5.4.4 SCR Temperature
Sensor Installation
Summary of Contents for Turbocor TT-300
Page 2: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Page 4: ...4 of 132 M SV 001 EN Rev E THIS PAGE INTENTIONALLY LEFT BLANK...
Page 12: ...12 of 132 M SV 001 EN Rev E THIS PAGE INTENTIONALLY LEFT BLANK...
Page 61: ...61 of 132 M SV 001 EN Rev E Compressor Components Figure 56 Stator Thermistor R T Curve 1...
Page 120: ...120 of 132 M SV 001 EN Rev E THIS PAGE INTENTIONALLY LEFT BLANK...
Page 130: ...130 of 132 M SV 001 EN Rev E Notes...