Option 90 - Defi ne remote sensor type
This allows type of remote sensor input type to
be defi ned. Press
+
until Option 90 is displayed,
use
V
and
Λ
to select required setting.
Setting 0
No remote sensor fi tted
Setting 1
Remote room or duct sensor fi tted, internal sensor disabled
(factory setting)
Setting 2
Remote limit sensor fi tted, refer to option 93 to defi ne
set-point
Setting 3
Confi gured as digital input for window, card reader or
teleswitch, refer to option 94 to defi ne o/c or s/c.
Setting 4
Outdoor sensor fi tted internal sensor active, outdoor
sensor used for display purposes only
Option 93 - Set limit sensor set-point
(option 90 set to 2)
This allows the thermostat limit sensor to be set,
typical application is fl oor Heating. Press
+
until
Option 93 is displayed, use
V
and
Λ
to select
required setting. If the temperature sensed by
the limit sensor exceeds the limit setting the
output will be turned off until the temperature
has dropped by 2°C. “F10” will fl ash in the display
while the output is disabled.
Setting
Any value between 20 - 50°C (Factory setting is 27°C)
Option 94 - Confi gure digital input switch type, “A” models only,
(option 90 set to 3)
This allows switch type of digital input to be
confi gured. Press
+
until Option 94 is displayed,
use
V
and
Λ
to select required setting.
Setting 0
Contacts NC, open circuit contact to force unit into
thermostat mode, short circuit contacts to return to
normal operation
Setting 1
Contacts NO, short circuit contacts to force unit into
thermostat mode, open circuit contacts to return to
normal operation (Factory setting)
Summary of Contents for TP9000
Page 32: ...TP9000 32 GB PL GR ES GR TP9000 1 0 1 0 33 1 1 34 1 2 37 2 0 2 1 39 2 2 39 2 3 40...
Page 35: ...Danfoss Heating 35 GB PL GR ES GR 1 2 OFF ON 2 DIL 37 TP9000 DIL...
Page 36: ...TP9000 36 GB PL GR ES GR 1 5 m 30 mm C L BSEN60730 1 3 mm 3amp...
Page 38: ...TP9000 38 GB PL GR ES GR TP9000 1 2 3 5 6 5 6 5 6 5 6...
Page 39: ...Danfoss Heating 39 GB PL GR ES GR 2 0 TP9000 40 2 1 TP9000 2 2...
Page 45: ...Danfoss Heating 45 GB PL GR ES GR 72 72 V 00 99 00 73 73 V 000 999 000 74 74 V 0 1...
Page 47: ...Danfoss Heating 47 GB PL GR ES GR 4 93 90 2 93 V 2 C F10 20 50 C 27 C 94 A 90 3 94 V 0 NC 1 NO...