![background image](http://html1.mh-extra.com/html/danfoss/tp9000/tp9000_installation-manual_3888928011.webp)
Danfoss Heating
11
GB
PL
GR
ES
GB
Option 34 - Select On/Off or Chrono-proportional
This allows the thermostat to be set to run in On/Off
mode or for a chrono-proportional cycle rate to be
selected. Press
+
until Option 34 is displayed, use
V
and
Λ
to select required setting.
0
On/Off
3
3 cycles per hour
6
6 cycles per hour (factory setting)
9
9 cycles per hour
12
12 cycles per hour
Option 35 - Set integration time (Option 34 set to 3, 6, 9 or 12)
(seek advice prior to adjusting)
This adjusts the integration time of the PI
algorithm to increase control accuracy. It is only
active if option 34 has been set to Chrono 3, 6,
9 or 12. It should only be adjusted after seeking
advice from the manufacturer. Press
+
until
Option 35 is displayed, use
V
and
Λ
to select
required setting.
2.5
Integration time set to 2.5% (factory setting)
5
Integration time set to 5%
10
Integration time set to 10%
Option 36 - Set temperature override rule
This establishes the degree of temperature override
available to the user. Press
+
until Option 36 is
displayed, use
V
and
Λ
to select required setting.
Setting 0
No limit (factory setting)
Setting 1
Limited to ±2°C
Setting 2
No override allowed
Summary of Contents for TP9000
Page 32: ...TP9000 32 GB PL GR ES GR TP9000 1 0 1 0 33 1 1 34 1 2 37 2 0 2 1 39 2 2 39 2 3 40...
Page 35: ...Danfoss Heating 35 GB PL GR ES GR 1 2 OFF ON 2 DIL 37 TP9000 DIL...
Page 36: ...TP9000 36 GB PL GR ES GR 1 5 m 30 mm C L BSEN60730 1 3 mm 3amp...
Page 38: ...TP9000 38 GB PL GR ES GR TP9000 1 2 3 5 6 5 6 5 6 5 6...
Page 39: ...Danfoss Heating 39 GB PL GR ES GR 2 0 TP9000 40 2 1 TP9000 2 2...
Page 45: ...Danfoss Heating 45 GB PL GR ES GR 72 72 V 00 99 00 73 73 V 000 999 000 74 74 V 0 1...
Page 47: ...Danfoss Heating 47 GB PL GR ES GR 4 93 90 2 93 V 2 C F10 20 50 C 27 C 94 A 90 3 94 V 0 NC 1 NO...