background image

1

TP5E

Electronic Programmable Room Thermostat

USER INSTRUCTIONS

Fig. 1

Fig. 3

Fig. 2

Fig. 5

Fig. 6

Fig. 4

The following table shows the factory pre-set programme,

which may be re-instated at any time by performing a

RESET.

Days 1 to 5 (Weekdays)         Days 6 & 7 (Weekend)

Setting Time Temp.

Setting Time Temp.

1

6:30

20

1

7:00

20

2

8:30

15

2

16:00

21

3

11:30

20

3

23:00

15

4

13:30

15

4

0:00

15

5

16:30

21

5

1:00

15

6

22:30

15

6

1:59

15

The factory pre-set programme for days 6 & 7 (Saturday

and Sunday) provides full heating throughout the day

until 23:00, after which the 15°C may be raised manually

to the level required using the

 

s

 

button. The manual

over-ride will last for up to one hour until midnight (0:00)

after which it can be used up to twice again to provide full

heating until 1:59 if required.

CHANGING THE SETTINGS

While  reviewing  the  settings  the  switching  time  and

control temperature may be changed using the

 + 

and

 -

(time) and

 

s

 

and

 

t

 

(temperature) buttons.

When changing the switching times it is not possible to

set the times out of sequence.
This important feature works like this:
Both number 1 time settings can be placed at any time of

the day, although they would usually be in the morning.
Each  of  the  time  settings  2  to  6  can  only  be  placed

between the previous setting and 1:59.
When using the

 - 

button to change settings 2 to 6 the

button stops responding when the previous setting time

is reached.  While using the

 + 

button to change settings

2 to 5, as later settings in the sequence are reached the

time continues to advance, (until 1:59 if the button is held

down), and all later settings reached are then changed to

the same time as the one being set.
Should this happen unintentionally and settings 2 to 6 are

all at the same undesirable time, use the PROG button to

get back to setting 1, days 1 to 5, then review and change

all the times and temperatures to the required settings. If

any times are intentionally set to the same time then the

temperature associated with the higher setting number

will be used to control the room temperature.

INITIAL START

-

UP

Slide the battery cover to the left to

reveal  the  programming  buttons

(PROG, 

+

-

). Slide the cover further

left to reveal the battery compartment.

Fit the batteries (supplied) making sure

the 

+

 ends align with the 

 

symbols at the back of the

compartment.  RESET  the  TP5E  as  described  below.

The blank display changes to that shown in fig. 1. (If the

actual air temperature in the proximity of the unit is higher

than 20°C the flame symbol will not be displayed). Slide

the battery cover to the right but leave the buttons visible.

RESET

The TP5E may be reset to the factory pre-set programme,

12:00 on day 1, and 20°C by pressing and holding down

the four buttons, temperature

 

and

 

t

 , 

time

 + 

and 

-

, until

the display becomes blank. This may be necessary after

a severe electrical storm or serious fluctuations in the

electricity supply, indicated by a malfunction or spurious

information such as 18:88 on the display.

SETTING THE CLOCK

Press the PROG button once; the colon

stops blinking, (see fig. 2). Use the

 +

and

 - 

buttons to set the time. Pressing

and releasing these buttons changes

the time by one minute, holding these

buttons down changes the time quickly.

When  the  time  is  correct  press  the

PROG button to start the clock; now

only  the  colon  and  day  number  are

displayed, (see fig. 3). Use the

 + 

and

 -

buttons  to  select  the  correct  day

number. (It is intended that day 1 is

Monday, therefore days 6 and 7 are

Saturday and Sunday - the weekend).

Press PROG to display the first setting,

(see fig. 4).

REVIEWING THE EXISTING

SETTINGS

Now each press of the PROG button

shows,  in  sequence,  the  twelve  set

times  and  their  associated  control

temperatures, starting at setting 1, days

1 to 5, and finishing at setting 6, days 6

& 7, (see figs. 4 to 6).  Pressing PROG

while setting 6, days 6 & 7 is shown

returns the TP5E to RUN mode.

Reviews: