background image

AN271156466186en-010201 

© Danfoss | Energy Meters | 2020.11 | 5

Installation & User Guide 

 

SonoSensor 30

Inlet/outlet conditions

 

SonoSensor 30 sizes from DN15 to DN50 don’t need any calming sections before and after the flow sensor. 
In order to maximize performance for sizes DN65, DN80 and DN100 it is necessary to have straight inlet 
and outlet flow conditions 5xDN before and 3xDN after the flow sensor.

2.3 Mounting of electronic unit

Direct mounting on ultrasonic flow sensor housing, turning every 90 ° C (only when the temperature of 
the flow does not exceed 90 ° C)

a) On the flow sensor with a thread connection

Wall mounting:

b) On the flow sensor with flange connection

Mounting on standard DIN-rail:

Important: It is forbidden to attach the electronic unit directly to the wall if there is a risk that on the wall can be 
condensed humidity or temperature of a surface of a wall can fall lower than 5°C. In this case, it is recommended 
to mount the calculator on the wall with an air gap not less than 5 cm.

5 x DN

flow

3 x DN

min 2

m

a

x 3

,5

Summary of Contents for SonoSensor 30

Page 1: ...Installation User Guide SonoSensor 30 Ultrasonic flow meter for heating and cooling applications...

Page 2: ...2 Danfoss Energy Meters 2020 11 AN271156466186en 010201 Installation User Guide SonoSensor 30 Note To ensure latest version of declaration please visit danfoss com...

Page 3: ...reparation 4 2 2 Installation of flow sensor 4 2 3 Mounting of electronic unit 5 3 Electrical wiring 6 3 1 Flow pulse cable connection 6 3 2 External power supply module if used 6 3 3 Wiring SonoSenso...

Page 4: ...he flow sensor is installed in the supply or return pipe of the system The flow sensor must be installed so that the direction of flow corresponds to the direction of the arrow on the flow sensor Calm...

Page 5: ...ectronic unit Direct mounting on ultrasonic flow sensor housing turning every 90 C only when the temperature of the flow does not exceed 90 C a On the flow sensor with a thread connection Wall mountin...

Page 6: ...module if used Terminal Nr Description 54 Mains supply 24 V AC DC bipolar 55 Mains supply 24 V AC DC bipolar 3 3 Wiring SonoSensor 30 to energy calculator Infocal 9 SonoSensor 30 in return pipe Infoca...

Page 7: ...sticker on the cover protecting electronic module manufacturer security seal 3 Mounting seal after installation 5 Power supply SonoSensor 30 can be powered from lithium battery 12 years life time or f...

Page 8: ...osal Battery AA cell Lithium thionyl chloride 620mg Lithium Approved deposit for lithium batteries PCBA with display and communication module Coppered epoxy laminate components soldered on PC TPE Elec...