Refer to the following wiring diagrams for proper connections.

Wiring diagram for 11101116

Wiring diagram for 11101126, 11101118, 11101115, 11101106

No adjustment is possible.

Do not attempt to disassemble or adjust the control.

For instructions on putting a pump with the Intrinsically Safe Control in service, refer to 

Initial Startup Procedure

 

in the 

Series 90 Pumps

Service Manual

.

Prior to installation, inspect packaging and unit for any damage. Do not continue installation if unit has visible signs of damage.

Danfoss is not responsible for the design of the control input circuit outside of the installed Mil-Spec connector. Proper design

on the entire system as noted in the applicable standards is required for safe usage in hazardous environments.

The EDC is designed to be controlled from a DC current source or voltage source. Pulse width modulation (PWM) is not required. But, if

a PMW signal is used, use a carrier frequency between 200 Hz and 4000 Hz. Do not use a pulse current of more than 120% of that

required for full output(refer to unit specifications below).

© Danfoss A/S, 202

 •

 • 

Hazardous location

Non-hazardou  location

V1 = 8.6 V

I1 = 250mA

P1 = 537.5mW

C1 = 0.4 µF

L1 = 0 mH

V1 = 8.6 V

I1 = 250mA

P1 = 537.5mW

C1 = 0.4 µF

L1 = 0 mH

PCP

C

D

A

B

Single 

coil

Dual 

coil

Hazardous location

Non-hazardous location

PCP

A

B

Exi Cl I, Div 1, Gp CD T4

Ex ia / AEx ia IIB T4 Ga

FM12ATEX0031X II 1 G Ex ia IIB T4 Ga

IECEx FMG 15.0008X Ex ia IIB T4 Ga

 = 16.0 V

I  = 110mA

P  = 440mW

C  = 0.4 µF

L  = 0 mH