Service Manual and
Axial Piston Pumps Series 20
Repair Instructions
L1003506
• Rev BA • Jun 2014
30
Mark the trunnion to facilitate correct
re-assembly later, and loosen the three screws on
each trunnion. Than remove the trunnion.
Once the trunnions have been removed, the
swash plate can be removed complete with
servo piston.
F000 114
Take care that the plastic shims are kept together
with the respective trunnions.
Individual parts of the servo piston can if
necessary, be replaced.
F000 245
F000 116
135
F000 113
35, 36, 37, 38
135
46, 47, 48
62 67 67
65
67
69
70
66
68
Cone bearing
Disassembly and Assembly