6
Installa
tion Instruc
tions
GB
Fan Con
Fan Auto
Sw On
1
MOT
WAX
2
DIL Switch options, shown in factory set position
.
DIL Switch Descriptions
Switch 1:
Fan Con
- Fan will run whenever thermostat is in
heating or cooling mode.
Fan
Auto
- Fan will run whenever temperature is
0.2°C or more above/below (depending on heat/cool
mode) setpoint. When temperature reaches setpoint,
the fan will switch off .
Switch 2:
MOT
- Motorised valve actuator selection.
WAX
- Wax valve actuator selection.
Mounting thermostat to the wallplate
To mount the thermostat to the wallplate, align the tabs on
the top of the thermostat with the apertures in the wallplate
and hinge the thermostat down, pressing fi rmly to engage
the securing clip in the wallplate.