PVSI with P-, T-, LX- and M-connection
PVSI is made of cast iron and works as an end plate. The PVSI with LX connection enables another valves
LS pressure to be shuttled to the pump when needed. The additional P- and T-port connections enables
an additional pump flow to a PVG 16 valve.
The PVSI with P-, T-, LX- and M-connection features:
•
Integrated LS pressure relief valve to tank
•
Threaded ports for P/T/LS/LX and M measuring gauge
PVSI with P-, T-, LX- and M-connection
PVSI with P-, T-, LX- and M-connection dimensions
77.4 [3.05]
11.5 [0.45]
70.8 [2.79]
35.2 [1.386]
35.3 [1.39]
30.5 [1.20]
20.4 [0.8]
109.4 [4.31]
40 [1.57]
112.7 [4.44]
95 [3.74]
23 [0.91]
PVSI with P-, T-, LX- and M-connection schematic
T
Lx
M
P
See part number table for details on maximum pressure capacity
Technical specification for A/B-port
Max. continuous pressure
Max. intermittent pressure
Max. rated flow
380 bar [5510 psi]
420 bar [6090 psi]
65 l/min [17 US gal/min]
Technical specification
Parameter
Minimum
Recommended range
Maximum
Fluid temperature
-30°C [-22°F]
30 to 60°C [86 to 140°F]
90° [194°F]
Fluid viscosity
4 mm
2
/s [39 SUS]
12 to 75 mm
2
/s [65 to 347 SUS]
460 mm
2
/s [2128 SUS]
Fluid cleanliness
23/19/16 (according to ISO 4406)
Operating temperature
Ambient: -30 to 60°C [-22 to 140°F]
Part number for PVSI with P-, T-, LX-, M-ports
Part number
P-port
T-port
LX-port
M-port
Mounting feet
Weight
157B2920
G3/8
G1/2
G1/8
G1/4
M8
0.47 kg [1.05 lb]
Technical Information
PVG 16 Proportional Valve Group
PVS End Plates
90 |
©
Danfoss | December 2018
BC00000211en-000901