background image

L1216285 • Rev BC • Sep 2015 

© Danfoss, 2015-09

Connection PVEO standard

Connector

A

B

Deutsch

pin 1

pin 4

Function

A (pin 1)

B (pin 2)

Neutral

0

0

Q:  P 

 A

U

DC

0

Q:  P 

 B

0

U

DC

Proportional Version

Deutsch version of PVEO /PVEO-R

Deutsch version of PVEA

Deutsch version of PVE-CI

Deutsch version of PVEA-F

ON/OFF Version

1
2

3

4

V310 358.A

1
2

3

4

V310 358.A

1
2

3

4

1

2

3
4

P301 834.A

1
2
3

4

5

6

V310 359.A

Function

Signal voltage

Neutral

U

S

 (pin 1) = 0.5 • U

DC

Q:  P 

 A

U

S

 (pin 1) = (0.5 

 0.25) • U

DC

Q:  P 

 B

U

S

 (pin 1) = (0.5 

 0.75) • U

DC

Float

V

F

 (pin 3) = U

DC

Pin layout: PVEO

The PVEO is available for simple ON/OFF 

actuation of the main spool.  It has a 4 pin 

Deutsch connector.

Pin layout: PVEA-F

The PVEA-F is available for float options. 

It has a 6 pin Deutsch connector where the 

float command has a dedicated pin. 

All features in the PVEA is also in the PVEA-F.

Pin layout: PVEA

The PVEA is available as the PVE for 

proportional control of the spool. It has a 4 pin 

Deutsch connector.

W

Warning

When PVEA-F is given float command it will 

actuate the spool into float state no matter 

what position in spool has or set point given 

to PVEA-F.

1. Vi (signal pin)

2. Sp (spool position)

3. Vneg (÷)

4. Vbat (+)

1. CAN_H

2. CAN_L

3. Vbat (+)

4. Vneg (÷ )

1. NC 2 (A-direction)

2. Vneg (÷)

3. Vneg (÷)

4. NC 4 (B-direction)

1. Vi (signal pin)

2. NC (not connected)

3. Vf (float)

4. Sp (spool position)

5. Vneg (÷)

6. Vbat (+)

Summary of Contents for PVEO

Page 1: ...upper Oil flow direction for standard assembled groups Richtung des Ölstroms für Standard Baugruppen Sens du débit pour ensembles standard To application To tank P A V310398A V310397A Mounting PVE y y Protect LVDT pin if present y y Ensure O rings are in place y y Do not over torque For full documentation see Technical Information PVG 16 L1214235 on www danfoss com V310397A 5 0 2 t m ...

Page 2: ...able for simple ON OFF actuation of the main spool It has a 4 pin Deutsch connector Pin layout PVEA F The PVEA F is available for float options It has a 6 pin Deutsch connector where the float command has a dedicated pin All features in the PVEA is also in the PVEA F Pin layout PVEA The PVEA is available as the PVE for proportional control of the spool It has a 4 pin Deutsch connector WWarning Whe...

Page 3: ...pacitor 100 uF Power consumption 3 5 W Oil viscosity Oil viscosity range 12 75 mm2 s 65 347 SUS min 4 mm2 s 39 SUS max 460 mm2 s 2128 SUS Bemærk Maksimum opstartsviskositet Note Max start up viscosity 2500 mm2 s Beachte Maximale Viskosität bei Inbetriebnahme Remarque Viscosité maximale au démarrage 2500 mm2 s Filtering in the hydraulic system Required operating cleanliness level 18 16 13 ISO 4406 ...

Page 4: ...ieux dommages C est la raison pour laquelle il est important d analyser chaque aspect de l application Les vannes proportionnelles étant utilisées dans de nombreuses conditions d exploitation et applications différentes le fabricant de l application porte l entière responsabilité de la sélection finale des produits et du respect des exigences en matière de rendement de sécurité et d avertissement ...

Reviews: