Specifications (continued)
Description
Units
Minimum
Maximum
Comment
Absolute accuracy of full range
% of full scale
3
1% typical. Offsets removed
when command is Ø.
Output settling time
ms
100
Depends on load
characteristics.
PWM frequency
Hz
33
4000
Some pins have a fixed
frequency, consult module
application program interface
(API).
Dither frequency
Hz
33
250
Increased in steps, see module
API.
Dither amplitude
A
0
0.5
Increased in steps, see module
API.
Over-current trip point
A
5
5.25
There is over-current protection
built into each output driver. If
the instantaneous current
exceeds the trip point, the
driver is latched off. GUIDE
application software can reset
the latch and attempt to drive
current again.
Technical Information
PLUS+1® MC0XX-1XX Controller Family
Inputs/outputs types and specifications
©
Danfoss | April 2018
L1321895 | BC00000227en-US0401 | 17