background image

Technical Information 

DP7XX Series PLUS+1® Mobile Machine Displays

L1315553

 • Rev DA • Dec 2013

7

Ordering Information

Model Features

Use the following table to identify model features. 

This is not a variant configurator.

D P 7

 

B  C D  E  F G

Product Configuration Model Code

A

B

C

D

E

F

G

Part number

DP700

01

01

01

02

04

01

11126309

DP700

02

01

01

02

04

01

11126310

DP700

03

01

01

02

04

01

11126311

DP710

01

01

02

02

04

01

11126322

DP710

02

01

02

02

04

01

11126323

DP710

03

01

02

02

04

01

11126324

DP720

01

02

02

02

04

01

11126325

DP720

02

02

02

02

04

01

11126326

DP720

03

02

02

02

04

01

11126327

A

Model Name

DP700

PLUS+1 Mobile Machine Displays

DP710
DP720

B

LCD Options

01

Value—Transmissive

02

Standard—Transmissive

03

High performance—Transmissive-Enhanced View TFT

C

Touch Screen Options

01

None

02

Projective Capacitive touch

D

Input/ Output Options

01

User configurable

1 CAN, 2 AIN/DIN, 2 DIN/AIN/FreqIn/Rheo/4-20 mA IN, DOUT

2 CAN, 2 DIN/AIN/FreqIn/Rheo/4-20 mA IN, DOUT

02

User configurable

1 CAN, 2 AIN/DIN, 2 DIN/AIN/FreqIn/Rheo/4-20 mA IN, 2 Video IN, DOUT

2 CAN, 2 DIN/AIN/FreqIn/Rheo/4-20 mA IN, 2 Video IN, DOUT

E

Flash Memory/ Application Key

02

512 MB/without application key

F

USB Port Type

04

USB device rear/USB host rear or front

G

Application Log (Vault Memory)

01

16 MB

Summary of Contents for PLUS+1 DP7 Series

Page 1: ...powersolutions danfoss com MAKING MODERN LIVING POSSIBLE Technical Information PLUS 1 Mobile Machine Displays DP7XX Series...

Page 2: ...s L1315553 Rev DA Dec 2013 2 Table of Revisons Date Page Changed Rev 05 Dec 2013 5 8 14 19 LCD option table added changed Panel Mounting Kit part number DA 14 Oct 2013 Various CA 12 Jul 2013 11 14 Cor...

Page 3: ...ng Information Model Features 7 Related Products 8 Danfoss Assembled Mating Connector Kits 8 Accessories 8 Inputs Outputs Inputs 9 Digital Analog 9 Multifunction 10 Encoder 11 Outputs 11 Digital Outpu...

Page 4: ...ils information regarding the PLUS 1 GUIDE software tool set that is used to build PLUS 1 applications DP7XX Series PLUS 1 Mobile Machine Displays Reference Documents Literature title Literature type...

Page 5: ...oduct you will have your own obligations under the licensing agreements which may include among other things the obligation to include a copy of these licenses or to include an offer of a physical cop...

Page 6: ...nfoss has no responsibility for any accidents caused by incorrectly mounted or maintained equipment y y Danfoss does not assume any responsibility for Danfoss products being incorrectly applied or the...

Page 7: ...02 02 04 01 11126326 DP720 03 02 02 02 04 01 11126327 A Model Name DP700 PLUS 1 Mobile Machine Displays DP710 DP720 B LCD Options 01 Value Transmissive 02 Standard Transmissive 03 High performance Tr...

Page 8: ...12 pin Deutsch WM 12S 10100741 12 pin connector kit 16 to 20 AWG Deutsch DTM06 12SA 12 pin connector 10102025 12 pin connector kit 20 to 24 AWG Deutsch DTM06 12SA 12 pin connector 10100944 Connection...

Page 9: ...5 2 Input impedance k 230 3 To 0 V Input impedance with pull down k 14 1 0 3 To 0 V Input impedance with pull up k 14 1 0 3 To 5 V Input impedance with pull up down k 7 27 0 2 To 2 5 V Normal Range M...

Page 10: ...22 Worst case error mA 0 2 I 3 Input impedance 100 2 To 0 V Shut off current mA 54 The displays do not have a Real Time Operating System RTOS Because of this the display should not be used as the mas...

Page 11: ...0 full speed Mbit s 12 Vbus input voltage V 4 4 Vbus input resistance k 70 Vbus 5 25 V Short circuit protection No damage V 0 36 Vbus output voltage V 4 75 5 25 Vbus output current A 0 5 Vbus short c...

Page 12: ...og to digital A D converter CAN Shield Description Unit Minimum Maximum Typical Comment Input impedance 0 68 F 1 Analog Input 5 V Only Description Unit Minimum Maximum Comment Allowed voltage at pin V...

Page 13: ...l Description 0 Display only 1 Display CAN0 2 Display CAN1 3 Display CAN0 1 4 CAN0 5 CAN1 6 CAN0 1 Selecting channel zero will not increase CAN traffic because of the PLUS 1 GUIDE Service Tool communi...

Page 14: ...ic Random Access Memory FRAM FRAM has a write endurance of over 100 trillion cycles that is ideal for datalogging 2kB is available for application Vault Memory DP7XX displays have 16 MB of flash vault...

Page 15: ...gh voltage High voltage can cause fire and or electrical shock if flammable gasses or chemicals are present can cause an explosion To protect against product damage and possible injury do not exceed p...

Page 16: ...IEC 60068 2 2 Fogging IEC 60068 Temperature change IEC 60068 2 14 Moisture ingress IEC 60529 Sunlight radiation ISO 16750 4 Temp humidity voltage IEC 60068 2 38 Chemical Condition Rating Chemical res...

Page 17: ...shading or mounting the display at an incline rather than the horizontal There is protective glass over the display screen Caution The protective glass will break if hit with a hard or heavy object I...

Page 18: ...ical Information DP7XX Series PLUS 1 Mobile Machine Displays L1315553 Rev DA Dec 2013 18 Installation Dimensions DP7XX in Millimeters Inches 235 20 9 26 163 50 6 44 9 90 0 39 42 60 1 68 USB 177 80 7 0...

Page 19: ...02 4 x 70 1 4X 6 0 25 0 24 0 01 Panel Cutout Stand Alone On Post Mount according to VESA Video Electronics Standards Association Mount Standards The VESA hole pattern for this display is 75 00 mm x 75...

Page 20: ...P2 Video power supply C1 P2 Power supply C5 P3 USB device D C4 P3 Video signal input 2 C3 P3 Video signal input 1 C1 P3 CAN0 High C5 P4 USB device GND C4 P4 Video signal input ground C3 P4 Video signa...

Page 21: ...inside of or close to metal machine surfaces where possible this simulates a shield which will minimize the effects of EMI RFI radiation y y Do not run wires near sharp metal corners consider running...

Page 22: ...present can cause an explosion To protect against product damage and possible injury before doing any electrical welding on a machine disconnect all power and signal cables connected to the display 1...

Page 23: ...Technical Information DP7XX Series PLUS 1 Mobile Machine Displays L1315553 Rev DA Dec 2013 23 Notes...

Page 24: ...ase contact the Danfoss Power Solution representative nearest you Products we offer Bent Axis Motors Closed Circuit Axial Piston Pumps and Motors Displays Electrohydraulic Power Steering Electrohydrau...

Reviews: