82 | 180R9383 | AQ121686503103en-000803
© Danfoss | 2023.03
Data sheet
Product type
Choice of material
.
Rubber
.
Plastic
.
Stainless steel
1.
.
Iron
.
Copper
.
Brass
.
Aluminium
Always use system components made
of corrosion proof materials
Non-corrosion proof materials
may cause damage
Choice of filter
2.
Install a 10 micron absolute filter with
pressure switch
< 10
m
m
abs.
> 10
m
m
Return filter with bypass valve and
poorer filterability than 10
m
will
damage the system
Filter location
3.
Locate the return filter in the return line
immediately before the tank
Placing the return filter upstream of the
final load may damage the pump
Pump location
4.
Pump always to be placed below water
surface level
Pump location above water surface
level will cause damage
Water supply
7.
System to be filled via filter
Filling system with unfiltered
water causes damage
6.
Pressure Relief valve
Pressure relief valve to be mounted
vertically or with vertical outlet and
connected to return hose or tank
Coupling the pressure relief valve outlet
directly to the pump inlet may damage
the pump
Suction conditions
5.
System to be dimensioned to provide
a suction pressure of the pump inlet of
max. 0.1 bar vacuum
Poor suction conditions will cause
malfunction and damage the pump
Design
Summary of Contents for PAHT G
Page 16: ...16 180R9383 AQ121686503103en 000803 Danfoss 2023 03 Data sheet Product type...
Page 41: ...180R9383 AQ121686503103en 000803 41 Danfoss 2023 03 Data sheet Product type Data sheet...
Page 57: ...180R9383 AQ121686503103en 000803 57 Danfoss 2023 03 Data sheet Product type...
Page 79: ...180R9383 AQ121686503103en 000803 79 Danfoss 2023 03 Data sheet Product type Guideline...