Building up the pump
unit
3.3 Orientation
The pump can be mounted/orientated in any
direction.
A: Elastic coupling
B: Bell housing
C: Motor shaft
We recommend a separation (“wall”) to separate
the inlet from the outlet end of the tank.
Monitoring
It is recommended to continuously monitor the
following conditions:
•
Water level in the tank
•
Filter contamination
•
Pressure (inlet- and outlet side of the
pump)
If alternative mounting is desired, please contact
the Danfoss Sales Organization.
Choose proper tolerances to ensure an easy
mounting of the elastic coupling without use of
tools.
Please take care to observe the recommended
length tolerances of the chosen coupling, as an
axial force on the pump shaft must be avoided.
3.2 Direction of rotation
Is indicated by means of an arrow at the label of
the pump.
Instruction