Instruction
Disassembling and assembling PAH 2-6.3, PAHT 2-6.3, PAHT C 2-6.3 and PAHT G 2-6.3
10
180R9094 / 521B0985 / DKCFN.PI.011.N5.02 / 09.2015
4. Mount the port plate in its right position
using the pin as guide.
3. Mount the O-ring on the flange.
Guide pin
6. Press the valve plate into the cylinder
barrel using a piece of plastic.
5. Mount the valve plate with seals on the
cylinder barrel.
8. Mount the cylinder barrel in the flange.
7. Check that the gap between the cylinder
barrel and the valve plate is 1.5-2.5 mm.