background image

2SW\PD

+LJK$PELHQW3DFN

114X7144

LBP
LBP
LBP
LBP

MBP
MBP
MBP
MBP
MBP
MBP
MBP

APP

UNIT

DESCRIPTION

CHASSIS

POWER SUPPLY

COMP

114X7155
114X7122
114X7145
114X7124
114X7127
114X7137
114X7128
114X7138
114X7119
114X7139

NTZ215
NTZ215
NTZ271
NTZ271

MTZ064
MTZ064
MTZ064
MTZ072
MTZ072
MTZ100
MTZ100

OP-LPHE215NTW07Q

OP-LPHE215NTW07V
OP-LPHE271NTW07V

OP-LPHE271NTW07Q

OP-MPZE108MTW07N
OP-MPZE108MTW07V
OP-MPZE108MTW07Q

OP-MPZE0121MTW07V

OP-MPZE121MTW07Q

OP-MPZE171MTW07V

OP-MPZE171MTW07Q

H4
H4
H4
H4
H4
H4
H4
H4
H4
H4
H4

230V/3/~60Hz

380V/3N/~60Hz
380V/3N/~60Hz

230V/3/~60Hz

230V/1N/~60Hz
380V/3N/~60Hz

230V/3/~60Hz

380V/3N/~60Hz

230V/3/~60Hz

380V/3N/~60Hz

230V/3/~60Hz

OP-MPZE108 - 121 - 171, OP-LPHE215 - 271

Instructions

4 |  © Danfoss | DCS (CC) | 2017.12

FRCC.PI.056.A2.02

Summary of Contents for Optyma OP-LPHE Series

Page 1: ...use of a forklift or pallet jack Use appropriate and safe lifting equipment Storeandtransporttheunitinanuprightposition Store the unit between 35 C and 60 C Don t expose the packaging to rain or corrosive atmosphere After unpacking check that the unit is com plete and undamaged 3 Installation precautions Do not braze as long the condensing unit is under pressure Neverplacetheunitinaflammableatmosp...

Page 2: ...essure Low Pressure Energize the unit It must start promptly If the compressor does not start check wiring conformity voltage on terminals and sequence phase 11 Check with running unit Check the fan rotation direction Air must flow from the condenser towards the fan Check current draw and voltage Check suction superheat to reduce risk of slug ging When a sight glass is provided observe the oil lev...

Page 3: ...PZE086MTW07V OP MPZE086MTW07N OP MPZE086MTW07Q H3 H3 H3 380V 3N 60Hz 230V 1N 60Hz 230V 3 60Hz OP MPZE060 068 086 OP LPHE108 136 2SW PD LJK PELHQW 3DFN 114X7140 LBP LBP LBP LBP LBP LBP MBP MBP MBP MBP MBP APP UNIT DESCRIPTION CHASSIS POWER SUPPLY COMP 114X7150 114X7153 114X7120 114X7141 114X7151 114X7146 114X7156 114X7117 114X7123 114X7157 NTZ048 NTZ048 NTZ048 NTZ068 NTZ068 NTZ068 MTZ018 MTZ018 MTZ...

Page 4: ... MTZ072 MTZ100 MTZ100 OP LPHE215NTW07Q OP LPHE215NTW07V OP LPHE271NTW07V OP LPHE271NTW07Q OP MPZE108MTW07N OP MPZE108MTW07V OP MPZE108MTW07Q OP MPZE0121MTW07V OP MPZE121MTW07Q OP MPZE171MTW07V OP MPZE171MTW07Q H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 H4 230V 3 60Hz 380V 3N 60Hz 380V 3N 60Hz 230V 3 60Hz 230V 1N 60Hz 380V 3N 60Hz 230V 3 60Hz 380V 3N 60Hz 230V 3 60Hz 380V 3N 60Hz 230V 3 60Hz OP MPZE108 121 171 ...

Page 5: ...o LP auto LP man HP man HP man HP auto HP auto P H t e s e r n a m P L t e s e r t u a P L AC1 16 A DC 11 LR 112A AC3 16 A 400 V 12 W AC1110 A 220 V When used acc to UL regulations 1 bar Pe 30in Hg Convertible reset KP 15 15A 17W 17B KP 17B 060 539366 060 539466 LP auto LP auto HP man HP auto Instructions Danfoss DCS CC 2017 12 5 FRCC PI 056 A2 02 ...

Page 6: ...C2 Run Capacitor Compressor C3 C4 Run capacitor Fan E1 Crankcase Heater F1 Main Switch F2 Overload Relay F3 F4 Fuse Control Circuit F5 Discharge Thermostat LBP only M1 Compressor M2 M3 Fan Motor K1 Compressor contactor K2 Start Relay R1 R2 Bleeder Resistor S1 Door Limit Switch Legend BK black BU blue BN brown GY grey RD red WH white Instructions 6 Danfoss DCS CC 2017 12 FRCC PI 056 A2 02 ...

Page 7: ...tor Compressor C3 C4 Run capacitor Fan E1 Crankcase Heater F1 Main Switch F2 Overload Relay F3 F4 Fuse Control Circuit F5 Discharge Thermostat LBP only M1 Compressor M2 M3 Fan Motor K1 Compressor contactor K2 Start Relay R1 R2 Bleeder Resistor S1 Door Limit Switch Legend BK black BU blue BN brown GY grey RD red WH white Instructions Danfoss DCS CC 2017 12 7 FRCC PI 056 A2 02 ...

Page 8: ...C2 Run Capacitor Compressor C3 C4 Run capacitor Fan E1 Crankcase Heater F1 Main Switch F2 Overload Relay F3 F4 Fuse Control Circuit F5 Discharge Thermostat LBP only M1 Compressor M2 M3 Fan Motor K1 Compressor contactor K2 Start Relay R1 R2 Bleeder Resistor S1 Door Limit Switch Legend BK black BU blue BN brown GY grey RD red WH white Instructions 8 Danfoss DCS CC 2017 12 FRCC PI 056 A2 02 ...

Page 9: ...C2 Run Capacitor Compressor C3 C4 Run capacitor Fan E1 Crankcase Heater F1 Main Switch F2 Overload Relay F3 F4 Fuse Control Circuit F5 Discharge Thermostat LBP only M1 Compressor M2 M3 Fan Motor K1 Compressor contactor K2 Start Relay R1 R2 Bleeder Resistor S1 Door Limit Switch Legend BK black BU blue BN brown GY grey RD red WH white Instructions Danfoss DCS CC 2017 12 9 FRCC PI 056 A2 02 ...

Page 10: ...der Resistor S1 Door Limit Switch Legend BK black BU blue BN brown GY grey RD red WH white 10 Danfoss DCS CC 2017 12 FRCC PI 056 A2 02 Danfoss can accept no responsibility for possible errors in catalogues brochures and other printed material Danfoss reserves the right to alter its products without notice This also applies to products already on order provided that such alterations can be made wit...

Reviews: