© Danfoss | DCS (ms) | 2020.05

8 | AN317523977313en-000201

Password: 12131400

In Service menu a unique

password for Service menu

can be entered.

 - Go to menu upper right

 - Go login

 - Go to settings

 - Go to Service Password

 - Enter new Service Password

Configuration continued

For further documents (Data sheet, SIL2 safety manual etc.) scan this QR code:

Danfoss A/S, 6430 Nordborg, Denmark

www.danfoss.com

LLS 007

7

8

Read and apply safety instructions contained in product documentation.

Direct current.

General warnings/precautions

-  Every use that is not described in this guide is considered incorrect and is not authorized by the manufacturer.
-  The LLS device should only be used with approved media listed under 

General specifications

. Use with other medias must be 

  validated by Danfoss before installation.
-  Verify that the installation and operating conditions of the device respects those specified in this guide, especially concerning 

  the supply voltage and environmental conditions.
-  All service and maintenance operations must be performed by qualified personnel.
-  Installation must comply with local standards and legislation.
-  Before carrying out any maintenance operations on the device, disconnect the device from the main power supply.
-  Before unscrewing the LLS device from the pipe or tank ensure that pipe or tank is empty and not under pressure.
-  Liability for injury or damage caused by incorrect use of the device lies solely with the user.
-  Depending on the application, the metallic part of the instrument may be hot or cold.
-  If media detection or non-detection by the level switch could generate a hazard the SIL version and specific instructions described 

  in the safety manual (periodic proof test) should be used. The SIL safety manual can be downloaded from Danfoss web site or by 

  scanning the QR code below.

LLS 007

7

8

LLS 007

7

8

22

Summary of Contents for LLS 4000

Page 1: ...G QDV 15 BSV BSV BSV ICF 25 6 5A EKE 347 AKS 4100 LLG BSV GD SVA SNV SNV SVA SVA LLG SNV SVA SFA DSV SVA LLS 4000 SVA SVA SCA X RT 260A RT 260A SNV SNV SVA SVA SNV SNV SNV SVA SCA X FIA FIA LLS 4000 F...

Page 2: ...b ft pre tightening 45 degrees clockwise rotation 32 mm LLS 4000U Alu gasket Clean joining surfaces Weld connector Clean for particles LLS 4000U Weld connector NPT Note Horizontal installation Recomme...

Page 3: ...4 V DC 25 Hand tighten clockwise 2 3 1 1 Fig 7 Cable with M12 female connector Red Green White Black 1 2 3 4 Color code M12 cable Danfoss M12 cables 034G7073 M12 cable female x 2 meter 034G7074 M12 ca...

Page 4: ...ON Yellow LED ON Red LED ON Green LED Flashing LLS 4000 4000U connected to Bluetooth device Configuration dependent Non SIL2 fully configurable SIL2 fixed configuration and only applicable for High Le...

Page 5: ...supply may be needed Max cycles 1 000 000 Mechanical Data Max medium viscosity 5000 cps Max working pressure 65 bar 943 psi Ambient temperature range 40 C to 65 C 40 F to 149 F Medium temperature ran...

Page 6: ...Danfoss DCS ms 2020 05 6 AN317523977313en 000201 2 8 0 78 3 4 NPT H32 1 4 5 6 M12x1 0 77 0 6 Fig 10 M12x1 G3 4 36 H32 71 3 2 34 20 15 142 4 19 5 LLS 4000 mm LLS 4000U in...

Page 7: ...s DCS ms 2020 05 AN317523977313en 000201 7 Configuration LLS Bluetooth app download Pin code 0000 1 2 3 download Search Danfoss 4 LLS 4000 ABCDEFGHIJKL LLS______ 1 2 3 LLS_______ 4 5 6 Configurable LL...

Page 8: ...ion and operating conditions of the device respects those specified in this guide especially concerning the supply voltage and environmental conditions All service and maintenance operations must be p...