Preparation

living connect® Z

 is an electronic radiator thermostat, in-

tended for use with water based room radiators. It can 

be controlled by a Z-Wave certified controller, which 

supports the appropriate command classes.

Z-Wave

controller

living connect® Z

sensor

living connect® Z

 is supplied with adapters for Danfoss 

RA valves and valves with M30 x 1.5 (K) connections, 

two alkaline AA batteries and a 2 mm Allen key.

Inserting the batteries

Remove the battery cover and insert two 

AA batteries. Make sure the batteries are 

correctly oriented.
Rechargeable batteries must not be 

used.
When replacing batteries the programme settings will 

be preserved, but after two minutes the settings for 

time and date are reset.

Installing 

living connect® Z

M

 must be flashing on the display prior to installing.

1.  Start by mounting the ap-

propriate adapter.

RA

K

2.  Tighten RA adapter using 

the Allen key, hand-tighten 

the K adapter (max. 5 Nm).

3.  Screw the thermostat onto 

the adapter and tighten by 

hand (max. 5 Nm).

4.  A large 

M

 flashes, press 

 to fix the thermostat.

Including the device to a network

Z-wave

controller

•  Ensure 

living connect® Z 

is factory reset.

•  Activate “Inclusion” on the Z-Wave controller.

•  Quickly press and release 

 on 

living connect® Z

.

•  Observe both controller and 

living connect® Z

 for 

status of the process.

Testing the connection

Press 

 for at least 3 seconds until 

M

 

is displayed.

Press   until 

LI

 is displayed.

Press 

 to test the connection.

LI

 disappears when the connection is 

made.

If no connection can be made, the 

alarm symbol   and the antenna 

symbol   flashes.

Display and buttons

Battery symbol

The set temperature

Network connection

Lock

Alarm

Use 

 to navigate the display and the menus and to 

set the temperature, and use 

 to select and confirm.

Temperature control and adjustment

The temperature is usually con-

trolled via the controller, but may 

be changed at any time using the 

thermostat’s buttons.

If this is done, the thermostat sends 

a message to the controller, which 

then syncronises other thermo-

stats in the same room.

18

19

20

21

26

25

24

23

Press

 

 

to change 

the temperature.

Excluding the device from the network

•  Activate “Exclusion” on the Z-Wave controller.

•  Quickly press and release 

 on 

living connect® Z

.

•  Observe both controller and 

living connect® Z

 for 

status of the process.

Re-installation mode

If the thermostat has been removed 

from the radiator and needs to be 

reinstalled (after being used), it is 

necessary to activate installation 

mode to prevent damage to the 

thermostat.
To enter installation mode:

•  Press 

 until 

M

 is displayed. 

•  Press 

 to withdraw the spindle. 

M

 flashes.

•  Reinstall the thermostat on the valve. 

•  Press 

 for approx. 3 seconds to fix the thermostat.

If the thermostat is moved to another room, make sure 

to make the necessary changes in the controller.

Factory reset

Remove the battery cover and take out one battery. 

Press and hold 

 for approx. 5 seconds, while re-

inserting the battery. 

living connect® Z

 is now factory 

reset and in mounting mode.

Wake up

A controller can only communicate with 

living connect® 

Z

, when the device is awake. The intervals when the 

thermostat is awake can be set using the “wake up 

command class”.

Press 

 to manually wake up the device. It will stay 

awake for 10 seconds and send out a node info.

Z-wave info

Device type

Slave

SDK

4.55

Software version

1.00

ProduktID

4

Explorer frames

YES

Implemented Z-Wave device classes

Z-Wave

Device Classes

Device Class

Implemented

Generic device

GENERIC_TYPE_THERMOSTAT

Specific device

SPECIFIC_TYPE_SETPOINT_THERMOSTAT

Supported and controlled

Z-Wave command classes

Z-Wave Command

Classes Supported

Description

COMMAND_CLASS_BATTERY

Get current battery status of 

living connect®

.

COMMAND_CLASS_CLIMATE_

CONTROL_SCHEDULE

Control a temperature 

offset to the thermostat 

setpoint of 

living connect®

The temperature offset is 

defined by schedules and 

schedule overrides.

COMMAND_CLASS_CLOCK

Set or get the current 

living 

connect®

 clock.

COMMAND_CLASS_

MANUFACTURER_SPECIFIC

Get manufacturer ID of 

system.

COMMAND_CLASS_MUL-

TI_CMD

A special Z-Wave command 

used by 

living connect®

 to 

encapsulate multiple com-

mands in one command 

and thereby conserve 

battery life.

COMMAND_CLASS_PROTEC-

TION

Set or get 

living connect®

 

local protection mode.

Possible local protection 

values are:

0 = no protection

2 = fully locked (tamper-

proof)

COMMAND_CLASS_THERMO-

STAT_SETPOINT

Set or get current thermo-

stat setpoint of 

living con-

nect®

. Heating setpoint is 

the only supported setpoint 

type.

COMMAND_CLASS_VERSION

Get version of product and 

command classes.

COMMAND_CLASS_WAKE_UP

A special Z-Wave command 

used by 

living connect® 

to 

synchronize communica-

tion with its controller.

Technical requirements and info

•  After a succesful inclusion the controller must send 

a WAKE_UP_INTERVAL_SET command to 

living con-

nect® Z

 in order to specify where and when 

living 

connect® Z

 should communicate wirelessly. If not, the 

thermostat cannot perform wake ups and the alarm 

 and antenna symbols   will flash.

•  The nodeID set in the WAKE_UP_INTERVAL_SET com-

mand must be for a permanently listening device 

which reponds to the commands sent from 

living 

connect® Z

. This means PC’s with USB sticks will only 

work if the PC is never turned off.

•  If 

living connect® Z

 does not get correct and timely 

replies (e.g. if the controller is turned of) it will auto-

matically switch to 30 minutes wake up intervals. If 

at next wake up the controller replies as expected, 

living connect® Z

 will switch back to the original wake 

up interval.

•  After sending the WAKE_UP_INTERVAL_SET com-

mand, the controller must assign return routes, so 

living connect® Z

 can reach its destination, i.e. the no-

deID set in the WAKE_UP_INTERVAL_SET command.

•  living connect® Z

 will not commence its periodic com-

munications if it is in “Mounting mode”. “Mounting 

mode” is for physical installation and should not be 

confused with “Inclusion”. Please see section “Install-

ing 

living connect® Z

, item 4” for instructions on how 

to leave “Mounting mode”.

•  Although 

living connect® Z

 supports single com-

mands, multi commands must always be used to 

ensure two years battery lifetime.

•  If multiple thermostats are installed in the same 

room, it is important that the controller ensures they 

all have the same schedule and the same setpoint.

Technical specifications

Thermostat type

Programmable electronic radia-

tor valve controller

Recommended use

Residential (pollution degree 2)

Actuator

Electro-mechanical

Display

Grey with back-light

Software classification

A

Control

PID

Transmission frequency

868.42 MHz

Transmission range

up to 30 m

Power supply

2 x 1.5V AA alkaline, class III

Power consumption

3 µW in standby, 

1.2 W when active

Battery life

2 years

Low battery signal

Battery icon will flash in display. 

If battery level is critical, the 

display will flash.

Ambient temperature

0 to 40 °C

Transportation tempera-

ture

-20 to 65 °C

Max. water temperature

90 °C

Temperature setting range 4 to 28 °C

Measurement interval

Measures temperature every 

minute

Clock accuracy

+/- 10 min./year

Spindle movement

Linear, up to 4.5 mm, max. 2 mm 

on valve (1 mm/s)

Noise level

<30 dBA

Safety classification

Type 1

Weight

177 g incl. RA adapter

IP class*

20

Tested for safety and EMC requirements as specified in EN 60730-1, 

EN 60730-2-9 and EN 60730-2-14.

Troubleshooting

Error code

Action

E1, E2, E3, E4

Contact your local Service Technician.

E5

The thermostat is not receiving the 

expected replies from the control 

system. Check that you have a Z-wave 

certified controller running and it 

has the necessary functionality to 

control the thermostat (see “Technical 

requirements”).

Safety precautions

The thermostat is not intended for children and 

must not be used as a toy.

Do not leave packaging materials where children 

may be tempted to play with them, as this is ex-

tremely dangerous.

Do not attempt to dismantle the thermostat as it 

contains no user-serviceable parts. If error code E1, 

E2 etc. is shown in the display or other defects ap-

pear, please return the thermostat to the distributor.

Indledende trin

living connect®

 

Z

 er en elektronisk radiatortermostat 

beregnet til brug med vandbaserede radiatorer. Den kan 

styres af en Z-Wave-certificeret styreenhed, der under-

støtter de relevante kommandoklasser.

Z-Wave controller

living connect® Z 

sensor

living connect®

 

Z

 leveres med adaptere til Danfoss RA-

ventiler og ventiler med M30 x 1,5 (K)-tilslutninger, 2 stk. 

AA alkaline batterier og en 2 mm unbrakonøgle.

Isætning af batterier

Fjern batteridækslet, og sæt to AA bat-

terier i. Sørg for, at batterierne vender 

rigtigt.
Der må ikke anvendes genopladelige 

batterier.
Ved udskiftning af batterierne bevares programindstil-

lingerne, men efter to minutter nulstilles indstillingerne 

for tid og dato.

Montering af 

living connect® Z

skal blinke på displayet, før montering kan foretages.

1.  Start med at montere den 

korrekte adapter.

RA

K

2.  Spænd RA-adapteren med 

unbrakonøglen. Spænd 

K-adapteren med hånden 

(maks. 5 Nm).

3.  Skru termostaten på 

adapteren, og spænd med 

hånden (maks. 5 Nm).

4.  Et stort 

M

 blinker, tryk på 

 for at fastgøre termo-

staten.

Tilmelding af termostaten til et netværk

Z-wave 

controller

•  Sørg for, at 

living connect®

 

er nulstillet til fabriksstan-

darden.

•  Aktivér “Tilmelding” på Z-Wave-styreenheden.

•  Tryk kortvarigt på 

 

living connect® Z

.

•  Processens status vises på både styreenheden og 

living 

connect® Z

.

Test af forbindelse

Tryk på 

 i mindst 3 sekunder, indtil 

M

 vises.

Tryk på  , indtil 

LI

 vises.

Tryk på 

 for at teste forbindelsen.

LI

 forsvinder, når forbindelsen er 

oprettet.

Hvis forbindelsen ikke oprettes, blinker 

alarmsymbolet   og antennesymbolet 

.

Display og knapper

Batterisymbol

Den indstillede temperatur

Netværksforbindelse

Børnesikring

Alarm

Brug 

 til at navigere på displayet og i menuerne og 

til at indstille temperaturen. Brug 

 til at vælge og 

bekræfte.

Temperaturstyring og -justering

Temperaturen styres sædvanligvis 

via styreenheden, men den kan når 

som helst ændres ved hjælp af ter-

mostatens knapper.

Hvis dette gøres, sender termosta-

ten besked til styreenheden, som 

derefter synkroniserer de øvrige 

termostater i rummet.

18

19

20

21

26

25

24

23

Tryk på 

 for at 

ændre temperaturen

Frakobling af enheden fra netværket

•  Aktivér “Frakobling” på Z-Wave-styreenheden.

•  Tryk kortvarigt på 

 

living connect® Z

.

•  Processens status vises på både styreenheden og 

living 

connect® Z

.

Genmonteringstilstand

Hvis termostaten har været fjernet 

fra radiatoren og skal genmonteres 

(efter at have været brugt), skal man 

aktivere genmonteringstilstand for at 

forhindre skader på termostaten.

Sådan skifter du til genmonteringstilstand:

•  Tryk på 

, indtil 

M

 vises. 

•  Tryk på 

 for at køre spindlen tilbage. 

M

 blinker.

•  Genmonter termostaten på ventilen. 

•  Tryk på 

 i ca. 3 sekunder for at fastgøre termostaten.

Hvis termostaten flyttes til et andet rum, skal man huske 

at justere styreenheden.

Nulstilling til fabriksstandard

Fjern batteridækslet, og tag det ene batteri ud. Tryk på 

og hold 

 inde i ca. 5 sekunder, og sæt samtidig batte-

riet i igen. 

living connect®

 

er nu nulstillet til fabriksstan-

darden og i monteringstilstand.

Aktivering

En styreenhed kan kun kommunikere med 

living con-

nect® Z

, når enheden er aktiveret. De intervaller, hvor 

termostaten er aktiveret, kan indstilles ved hjælp af 

“aktiveringskommandoklassen”.

Tryk på 

 for at aktivere enheden manuelt. Den vil 

være aktiveret i 10 sekunder og udsender en nodeop-

lysning.

Z-wave-oplysninger

Enhedstype

Slave

SDK

4,55

Softwareversion

1.00

Produkt-id

4

Explorer-rammer

JA

Implementerede Z-Wave-enhedsklasser

Z-Wave

Enhedsklasser

Enhedsklasse

Implementeret

Generisk enhed

GENERIC_TYPE_THERMOSTAT

Specifik enhed

SPECIFIC_TYPE_SETPOINT_THERMOSTAT

Understøttede og styrede

Z-Wave-kommandoklasser

Z-Wave-kommando

Understøttede klasser

Beskrivelse

COMMAND_CLASS_

BATTERY

Se den aktuelle batteristatus for 

living connect®

.

COMMAND_CLASS_

CLIMATE_CONTROL_

SCHEDULE

Indstiller et temperatur-offset til 

termostatsætpunktet for 

living 

connect®

. Dette temperatur-

offset defineres af tidsplaner og 

tilsidesættelser af tidsplaner.

COMMAND_CLASS_CLOCK Indstil eller hent det aktuelle 

living connect®

-ur.

COMMAND_CLASS_

MANUFACTURER_SPECIFIC Hent systemets producent-id.

COMMAND_CLASS_

MULTI_CMD

En særlig Z-Wave-kommando, 

der bruges af 

living connect®

 

til at sammenfatte flere kom-

mandoer i én kommando for at 

reducere batteriforbruget.

COMMAND_CLASS_

PROTECTION

Indstil eller hent lokal beskyt-

telsestilstand (børnesikring) for 

living connect®

. Mulige værdier 

for lokal beskyttelse er:

0 = ingen beskyttelse

2 = fastlåst (kan ikke manipuleres)

COMMAND_CLASS_

THERMOSTAT_SETPOINT

Indstil eller hent det aktuelle 

termostatsætpunkt for 

living 

connect®

. Opvarmningssætpunkt 

er den eneste understøttede 

sætpunktstype.

COMMAND_CLASS_

VERSION

Hent produktversion og version 

for kommandoklasser.

COMMAND_CLASS_

WAKE_UP

En særlig Z-Wave-kommando, 

der bruges af 

living connect® 

til 

at synkronisere kommunikation 

med dens styreenhed.

Tekniske krav og oplysninger

•  Efter en vellykket tilmelding skal styreenheden sende 

en WAKE_UP_INTERVAL_SET-kommando til 

living con-

nect® Z

 for at angive, hvor og hvornår 

living connect® Z

 

skal kommunikere trådløst. Hvis ikke, kan termostaten 

ikke udføre aktiveringer, og alarmsymbolet   og 

antennesymbolet   blinker.

•  Node-id’et indstillet i WAKE_UP_INTERVAL_SET-

kommandoen skal være til en permanent lytteenhed, 

der reagerer på kommandoer sendt fra 

living connect® 

Z

. Det betyder, at pc’er med USB-stik kun fungerer, hvis 

pc’en aldrig slukkes.

•  Hvis 

living connect® Z

 ikke får korrekte og rettidige 

svar (f.eks. hvis styreenheden er slukket), skifter den 

automatisk til 30 minutters aktiveringsintervaller. Hvis 

styreenheden ved næste aktivering svarer som forven-

tet, skifter 

living connect®

 

Z

 tilbage til det oprindelige 

aktiveringsinterval.

•  Efter afsendelse af kommandoen WAKE_UP_INTER-

VAL_SET skal styreenheden tildele returruter, så 

living 

connect® Z

 kan nå sin destination, dvs. det- node-id, der 

er angivet i kommandoen WAKE_UP_INTERVAL_SET.

•  living connect® Z

 påbegynder ikke regelmæssig kom-

munikation, hvis den er i “Monteringstilstand”. “Monte-

ringstilstand” bruges ved fysisk installation og må ikke 

forveksles med “Tilmelding”. Se afsnittet “Montering 

af 

living connect®

 

Z

, punkt 4” for vejledning i, hvordan 

man forlader “Monteringstilstand”.

•  Selvom 

living connect® Z

 understøtter enkeltkomman-

doer, skal der altid bruges multikommandoer for at 

sikre to års batteritid.

•  Monteres der flere termostater i samme rum, er det 

vigtigt, at styreenheden sikrer, at de alle har den 

samme tidsplan og det samme sætpunkt.

Tekniske specifikationer

Termostattype

Programmerbar elektronisk radia-

tortermostat

Anbefalet brug

Bolig (forureningsgrad 2)

Aktuator

Elektromekanisk

Skærm

Grå med baggrundsbelysning

Softwareklasse

A

Styring

PID

Sendefrekvens

868,42 MHz

Sendeområde

op til 30 m

Strømforsyning

2 x 1,5 V AA alkalisk, klasse III

Strømforbrug

3 µW i standby, 1,2 W hvis aktiv

Batteriets levetid

2 år

Signal ved lavt batteri

Batteriikon blinker i displayet. Hvis 

batteriniveauet er kritisk, blinker 

displayet.

Omgivelsestemperatur

0 til 40 °C

Transporttemperatur

-20 til 65 °C

Maks. vandtemperatur

90 °C

Temperaturindstillings-

område

4 til 28 °C

Måleinterval

Måler temperatur hvert minut

Urets nøjagtighed

+/- 10 min./år

Spindelvandring

Lineær, op til 4,5 mm, maks. 2 mm 

på ventil (1 mm/s)

Støjniveau

<30 dBA

Sikkerhedsklasse

Type 1

Vægt

177 g inkl. RA-adapter

IP-klasse*

20

Testet for sikkerhed og EMC-krav i henhold til EN 60730-1, EN 

60730-2-9 og EN 60730-2-14.

Fejlfinding

Fejlkode

Udførte forbedringer

E1, E2, E3, E4

Kontakt din lokale servicetekniker.

E5

Termostaten modtager ikke de forven-

tede svar fra styresystemet. Kontrol-

lér, at du har en Z-wave-certificeret 

styreenhed kørende, og at den har de 

nødvendige funktioner til styring af 

termostaten (se “Tekniske krav”).

Sikkerhedsregler

Termostaten er ikke beregnet til børn og må ikke 

bruges som legetøj.

Efterlad ikke emballagen, hvor børn kan blive fristet 

til at lege med den, da det er særdeles farligt.

Forsøg ikke at skille termostaten ad. Den indeholder 

ikke dele, som en bruger kan reparere. Hvis fejlkode 

E1, E2 osv. vises på displayet, eller hvis der opstår 

andre defekter, bedes du returnere termostaten til 

forhandleren.