Input

Type

Range

Description

Enbl_RecheckCRC

BOOL

——

Determines if the I/O module CRC is periodically checked to ensure the device’s
configuration matches the function block’s configuration.
T: The CRC is requested from the I/O module and compared every 5 seconds.
F: The CRC is only requested from the I/O module during initialization.

Enbl_ResetTest

BOOL

——

Determines if the I/O module volatile memory is periodically checked to ensure
the device has not lost volatile configuration information due to temporary loss
of power.
T: Volatile information is requested from the I/O module and compared every 1
second.
F: Volatile memory is not checked after initialization and temporary loss of
power to the I/O module may go undetected.

BusRecvryTm

U16

0–65535

BusRecvryTm sets the time the I/O module CAN port waits after going into a
“bus off” condition before attempting to go back on the bus.
1000 is 1 ms.

DriverRecvryTm

U16

0–65535

DriverRecvryTm sets the time the I/O module CAN port waits after a CAN error
causes the driver to reset before attempting to go back on the bus.
1000 is 1 ms.

RepTime_Supply

U16

0–65535

Determines how often the Power, Sensor Power, and CAN Shield input values
are transmitted from the I/O module.
1000 is 1 ms.

RepTime_DigAn_In

U16

0–65535

Determines how often the DigIn and AnIn values are transmitted from the I/O
module.
1000 is 1 ms.

RepTime_MF_In

U16

0–65535

Determines how often the MFIn values are transmitted from the I/O module.
1000 is 1 ms.

Inputs – Power Supply

The status of power supply input on the connector and pin C1p02 is described.

Signal

Type

Direction

Range

Description

C1p02_Pwr

Bus

——

——

AnIn U16

Input

0 – 32767

Analog input AD count.
Due to CAN message optimization, this value is approximated by scaling the Volt
signal.

Volt U16

Input

0 – 55015

Analog input voltage
100 is 100 mV.

Updated BOOL

Input

——

True when the AnIn and Volt signals are refreshed.

Inputs – CAN Shield

The status of analog and CAN0 shield inputs on the connector and pin C1p05 is described.

Signal

Type

Direction

Range

Description

C1p05_AnIn

Bus

——

——

AnIn U16

Input

0 – 32767

Analog input AD count.
Due to CAN message optimization, this value is approximated by scaling the Volt
signal.

Volt U16

Input

0 – 5753

Analog input voltage
100 is 100 mV.

Updated BOOL

Input

——

True when the AnIn and Volt signals are refreshed.

User Manual

PLUS+1® Compliant IX012-010 Function Block

IX012-010 Function Block

 

©

 Danfoss | July 2018

11063398 | AQ00000107en-US0101 | 5

Summary of Contents for IX012-010

Page 1: ...User Manual PLUS 1 Compliant IX012 010 Function Block www danfoss com...

Page 2: ...Revision history Table of revisions Date Changed Rev July 2018 Rebranding 0101 June 2009 AA User Manual PLUS 1 Compliant IX012 010 Function Block 2 Danfoss July 2018 11063398 AQ00000107en US0101...

Page 3: ...s and Signal Overview 8 Configuring Communications 9 Variable Addressing Mode 9 Predefined Addressing Mode 9 Fixed Addressing Mode 9 Volatile Parameters 9 Non Volatile Parameters 10 Timing Configurati...

Page 4: ...e The CAN messages use 11 bit identifiers in this mode 2 Fixed ID addressing mode The I O module Tx and Rx message identifiers are determined directly by setting Tx ID and Rx ID The CAN messages use e...

Page 5: ...ines how often the Power Sensor Power and CAN Shield input values are transmitted from the I O module 1000 is 1 ms RepTime_DigAn_In U16 0 65535 Determines how often the DigIn and AnIn values are trans...

Page 6: ...h Supply Voltage The internal Pull Up resistor is connected to an internal 5 V The internal Pull Down resistor is connected to Ground PinConfig1 U16 Output 0 3 Sets the maximum input voltage to allow...

Page 7: ...ear in both the Input and Output buses Signal Type Direction Range Description CAN Bus CommStatus U16 Input 1 8 255 Current status of communication with the I O module 0 CAN message transmission is di...

Page 8: ...on block requires I O module hardware using protocol version 2 00 to 2 99 ProtocolVersion U16 Input 0 65535 I O communication protocol version used by the I O module hardware 200 is version 2 00 Conne...

Page 9: ...module In this mode the I O module reads the N1 value stored in non volatile memory EEPROM Because the function block and the I O module use different default addressing modes as long as the N1 value...

Page 10: ...ion on a CAN bus Use the PLUS 1 CG150 USB CAN gateway and CANKing software to view CAN bus loads PLUS 1 I O modules communicate with their associated controllers over a CAN bus System developers can a...