Service instruction
Disassembling and assembling iSave 21
4
180R9219 / 521B1171 / DKCFN.PI.003.K3.02 / 11.2013
3 .
Disassembling the
pressure exchanger
1.
Unscrew the bolts in the flange.
3.
Gently push out the flange.
2.
Screw in the two M8 bolts.
4.
Wet the shaft and shaft seal with clean
filtered water. Gently lever the shaft
assembly free using 2 screwdrivers.
5.
Unscrew the bolts in the flange.
6.
Gently remove the flange.
Note: Loose parts on the inside of the flange .