Ikargo2 Maintenance Recommendations
This product is designed for use in an industrial environment that may shorten the product's lifespan. Use
these recommendations to maximize the lifespan of the product.
•
Use the hook/belt provided with the transmitter to prevent the transmitter from falling
•
Do not clean the transmitter with solvents or pressurized water; use a damp cloth or soft brush for
cleaning
•
If the push buttons show signs of deterioration, contact the Authorized Technical Service for repair
•
Check if the battery contacts are correct, otherwise replace them.
•
Be sure to recharge or replace battery regularly
Maintenance tips quick reference
Ikargo2 Troubleshooting
The transmitter has status monitoring LED's which help identify irregularities. The most common signals
are contained in the table below:
LED color | Frequency
Pulse Frequency
Description
Action
Green | continuous
The transmitter works properly. Operation
mode is OK.
No action needed.
Green | pulses
STANDBY mode. If transmitter is 4 minutes
ON and no action has been taken.
Press START to return to operation mode.
Red | slow pulses
Low battery signal.
In 5 minutes you need to replace with full
battery.
Red | fast pulses
EEPROM module missing or corrupted.
Check EEPROM module or reprogram if
necessary.
Red | double pulses
A maneuver is activated at transmitter start up
process; may indicate hardware damage if no
order is active.
Release maneuver or replace transmitter if
necessary.
Red | continuous
General hardware failure or damage.
Replace transmitter