background image

IK3 maintenance tips

This product is designed for use in an industrial environment that may shorten the product's lifespan. Use

these tips to maximize the lifespan of the product.

Use the hook/belt provided with the transmitter to prevent the transmitter from falling

Do not clean the transmitter with solvents or pressurized water; use a damp cloth or soft brush for

cleaning

If the push buttons show signs of deterioration, contact the Authorized Technical Service for repair

Check if the battery contacts are correct, otherwise replace them.

Ensure that the product is supplied with AAA alkaline batteries or has a rechargeable battery

Be sure to recharge or replace battery regularly

Maintenance tips quick reference

Troubleshooting (400-900 MHz)

The transmitter has status monitoring LED's which help identify irregularities. The most common signals

are contained in the table below:

Color and frequency

Pulse frequency

Description

Action

Green | continuous

Working

Operate

Green | slow pulses

Latency; no action has been taken for some time

Press START to return to operation

mode

Red | slow pulses

Low battery signal

Replace or recharge battery

Red | fast pulses

EEPROM module missing or corrupt

Check EEPROM and reprogram if

necessary

Red | double pulses

A maneuver is activated at transmitter start up process;

may indicate hardware damage if no order is active

Release maneuver or replace

transmitter if necessary

Red | continuous

General hardware failure

Replace transmitter

Troubleshooting 2.4 GHz

The transmitter has status monitoring LED's which help identify irregularities. The most common signals

are in the table below:

LED color | Frequency

Pulse Frequency

Description

Action

Blue / fast pulses

Starting the system,establishing

communication with radio and EEPROM.

Wait

Blue | continuous

Stand-by. Set up system, waiting user’s action. Press START to enter Operation mode.

User Manual

Remote Control IK3 Transmitters

Maintenance

 

10 | 

©

 Danfoss | May 2021

BC290857689420en-000201

Summary of Contents for IK3

Page 1: ...User Manual Remote Controls IK3 Transmitters www danfoss com...

Page 2: ...s Date Changed Rev May 2021 Added trouble shooting and start up information for TR2400 0201 February 2019 Rebranded to Danfoss Power Solutions 0101 User Manual Remote Control IK3 Transmitters 2 Danfos...

Page 3: ...description 9 Maintenance Maintenance tips 10 Troubleshooting 400 900 MHz 10 Troubleshooting 2 4 GHz 10 Charger and battery Charger and battery 12 CB70 and BT27IK specifications 12 Setting up the CB70...

Page 4: ...llage et 2 l utilisateur de l appareil doit accepter tout brouillage radio lectrique subi m me si le brouillage est susceptible d en compromettre le fonctionnement IK3 General Safety The following saf...

Page 5: ...s press STOP before plugging in tether cable if applicable Remove the Tether connection on the transmitter First if applicable Do not operate product when visibility is limited Make sure product is co...

Page 6: ...3 5 6 8 9 10 1 Label for crane identification 2 LED 3 Maneuver elements 4 Contact key 5 Start push button 6 STOP button 7 Optional Range limiter 8 External and extractable EEPROM module 9 Battery 10...

Page 7: ...achine and battery level only if it has been pre programmed crane xx1 LED pulse Display option 4 Press the start button The green LED will now light to indicate the transmitter is transmitting Once th...

Page 8: ...play the identification of the machine as well as the battery level if it has been pre programmed 4 Press the START button and wait for the status LED to turn to fixed green LED status green The statu...

Page 9: ...ches Removable EEPROM External Battery model BT27IK Battery life 10 hours Response Time 100ms Operating temperature range 20 C to 70 C 4 F to 158 F Storage Temperature Range 24h 25 C to 75 C 13 F to 1...

Page 10: ...w Color and frequency Pulse frequency Description Action Green continuous Working Operate Green slow pulses Latency no action has been taken for some time Press START to return to operation mode Red s...

Page 11: ...tion mode Red slow pulses EEPROM Error EEPROM module is missing or corrupted Check EEPROM module or reprogram if necessary Red double pulses Radio Error Radio communication error Replace transmitter R...

Page 12: ...15 Vca 60 Hz DC power supply From 10 5 V to 35 V BT27IK battery Specification Value Voltage 4 8 V Capacity 2700 mAh NiMH Charging temperature From 0 C to 45 C Discharge temperature From 20 C to 50 C A...

Page 13: ...cycles and is largely dependent on the conditions of use To maximize the lifespan of the batteries and battery charger follow these recommendations Do not recharge the battery until it is completely f...

Page 14: ...CB70 battery charger dimensions Dimensions in mm 131 60 179 80 128 50 40 34 50 User Manual Remote Control IK3 Transmitters Charger and battery 14 Danfoss May 2021 BC290857689420en 000201...

Page 15: ...Danfoss Power Solutions US Company 2800 East 13th Street Ames IA 50010 USA Phone 1 515 239 6000 Danfoss Power Solutions Trading Shanghai Co Ltd Building 22 No 1000 Jin Hai Rd Jin Qiao Pudong New Distr...

Reviews: