Electric Displacement Control (EDC), option A2 (12V) / A3 (24V)
Z
Mounting flange
Shaft
2x 64.2 ±0.8
206 ±2.5
Shaft
Mounting flange
Control solenoid
connector "C2"
Deutsch DT04-2P
paint free
Control solenoid
connector "C1"
Deutsch DT04-2P
paint free
Case gauge port "M14"
Port ISO 1926-1 - 7/16-20
∅
21 max clearance dia for fitting
CL
CL
P700 332 58
147.3 ±1.2
120.1 ±1.2
173 ±2.5
58 ±0.8
-45
1
2
P301 320
W (2:1)
Control solenoid Connector “C1” & “C2”
Pin
Assignment
OR
Pin
Assignment
1
Supply
1
Ground
2
Ground
2
Supply
Please contact Danfoss representative for specific installation drawings.
Technical Information
H1 Axial Piston Single Pumps, Size 045/053
Controls
52 |
©
Danfoss | May 2017
11063344 | BC00000059en-US1001