Die Cage Assembly Instructions
1. Assure all components are free from dirt and other contaminants prior to assembly.
2. Position back plate on a table with the slots toward the assembler.
3. Lightly lubricate the spring plate with high efficiency PTFE grease (Danfoss part number T-400-G). See illustration for location of
lubricant.
4. Position spring plate on top of the back plate with the lubricated side up. Orientation must be the same as the back plate.
5. Install all eight springs into the slots of the spring plate. Allow the excess of the spring to overhang the outside diameter of the spring
plate.
6. Install all eight roll pins into the backside of the dies. Allow .20” of roll pin to protrude.
7. Install all eight crimp dies within the slots of the spring plate. See illustration for insertion.
8. Lightly lubricate the front plate with high efficiency PTFE grease (Danfoss part number T-400-G). See illustration for location of
lubricant.
9. Position the front plate on top of the crimp dies. The part number must be to the topside of the cage.
10. Install all four spacers in line with the tapped and clearance holes.
11. Install one 3” long button head screw. Tighten into position with “T” nut.
12. Install three 2 5/8” long button head screws. Tighten securely.
13. Stamp the same number, following the FT1204-100- located in the cavity of the crimp die, on the front plate after the FT1307-200-.
14. Rub white paint into the stamped numbers.