background image

3

ERROR FREE PROGRAMMING.

ON/OFF times cannot be set out of sequence. The limits of adjustment
are:
Setting 1 (first ON) 12:00am to 11:59pm (normally in the morning).
Settings  2  to  6  (first  OFF  to  last  OFF)  anywhere  between  the
previous Setting and 23 hours 59 minutes after Setting 1.
The - button stops responding when the previous Setting is reached,
but  the  +  button  continues  to  its  limit,  also  changing  any  later
Settings that would have been overlapped.
While  becoming  familiar  with  the  Setting  Sequence  the  ON/OFF
times  may  become  grouped  together.  If  this  should  happen  use
NEXT ON/OFF to select Setting 1, then check/alter each Setting in
turn, using + or -, until the desired programme is entered.

NOTES ON TYPICAL DISPLAYS (See left)

Fig. 1

Immediately following a manual RESET [RUN mode with
colon blinking]

Fig. 2

SET TIME and DAY mode [colon steady, day, hours and
minutes blink]

Fig. 3

SET FIRST ON TIME [“CH”]
[setting number and day shown, “ON” blinks]

Fig. 4

SET FIRST OFF TIME [“CH”]
[setting number and day shown, “OFF” blinks]

Fig. 5

SET LAST OFF TIME AFTER MIDNIGHT
[day when output will switch off blinks]

Fig. 6

SET “HW” FIRST ON TIME
[setting number and day shown, “ON” blinks]

Fig. 7

Typical “CH” ALLDAY, “HW” AUTO programme with “HW”
+1HOUR selected.

When programming in 7 day mode, the day being set appears in the
display, (see typical displays). In 24 hour mode,  the day only appears
in SET TIME mode. When programming in 5 day/2 day mode then the
days will show as MOTUWETHFR or SASU.
Should  the  unit  be  disconnected  from  the  mains  a  small  battery
symbol will blink on the left hand side of the display.

FACTORY PRE-SET PROGRAMME

The following ON/OFF times are programmed at the factory and
are re-instated by pressing the recessed R/S button behind the
flap.

Every day for 24 Hour control

o r

Monday to Friday for 7 Day or 5/2 Day control

Saturday and Sunday

f o r

7 Day or 5/2 Day control

SETTING NO.

O N / O F F

T I M E

SETTING NO.

O N / O F F

T I M E

2 ON/OFF’s

3 ON/OFF’s

2 ON/OFF’s

3 ON/OFF’s

1
2

-
-

3
4

1
2
3
4
5
6

O N

O F F

O N

O F F

O N

O F F

6 . 3 0 a m
8 . 3 0 a m

1 2 . 0 0 p m
1 2 . 0 0 p m

5 . 0 0 p m

1 0 . 3 0 p m

1
2

-
-

3
4

1
2
3
4
5
6

O N

O F F

O N

O F F

O N

O F F

7 . 3 0 a m

1 0 . 0 0 a m
1 2 . 0 0 p m
1 2 . 0 0 p m

5 . 0 0 p m

1 0 . 3 0 p m