background image

2

Sequence of button presses whilst adjusting time, day and programme settings

Read the section “Error free programming” first.

Press and r or - to change the time by one minute. Press and hold down + or - to change the time quickly.

NOTE: 

The installer has set switches on the rear of the FP715 to select either 24 hour operation (same programme repeated each day) or

5/2 day operation (one programme repeated Monday to Friday with a different programme repeated Saturday and Sunday) or 7 day operation
( a different programme for each day). The installer has also selected either 2 ON/OFFs or 3 ON/OFFs per day

SELECTING THE OPERATING MODE

Behind the flap are two SELECT buttons, one each for Central
Heating ( 

 ) and Hot Water ( 

 ).

The operating modes available are:
ON

- The output is on constantly.

OFF

- The output is off constantly, 1HR is pressed.

AUTO

- The output switches on and off to the set programme.

ALLDAY

- The output switches on at the 1st ON time and  stays on

until the last OFF time.

MANUAL OVERRIDES

While in OFF, AUTO or ALLDAY modes the plus one hour (+1HR)

button can be used to switch from off to on for just one hour, or to

extend an existing on period by one hour. The extra hour is cancelled

by pressing the button again, pressing the MAN button, or when an on

event is reached.
While in AUTO or ALLDAY modes pressing the manual (MAN) button

will switch an output which is on to off, and vice versa. This over-ride

will last only until the next programmed switching event is reached,

when the automatic programme will resume control, or until the button

is pressed again.
When the above overrides are selected a bar appears in the display

against the appropriate legend.

Button Sequence

FP715

Typical Displays

Step

Press

Action

1

PROG

To enter programming mode (Fig 2)

2

DAY

To select day of week, repeat until display shows

current day (Fig 2)

3

+ or -

To adjust time of day (Fig 2)

4

PROG

To enter CH ON/OFF programming mode (Fig 3)

5

+ or -

To adjust 1st CH ON time (setting no 1, Fig 3)

6

NEXT

To step to 1st CH OFF time (setting no 2, Fig 4)

7

+ or -

To adjust 1st CH OFF time (setting no 2, Fig 4)

8

NEXT

Repeat step 5-7 until all ON/OFF times are as

required

9

-

If unit is set for 24 hour operation, go to step 13, otherwise

go to step 10

10

DAY

To advance to next day.  If a different programme from

previous day is required go back to step 7.

If the same programme as previous day is required

go to step 11.

11

COPY

To copy previous days' programmes to current day

12

-

Repeat steps 10 an d11 until all days are programmed

13

PROG

To enter HW ON/OFF programming mode

14

+ or -

To adjust 1st HW ON time (setting no 1)

15

NEXT

To step to 1st HW OFF time

16

+ or -

To adjust 1st HW OFF time

17

NEXT

Repeat steps 14 - 16 until all HW events are set

18

PROG

To return to RUN mode

Fig 1

Fig 2

Fig 3

Fig 4

Fig 5

Fig 6

setting no